Retina Consultants of Houston, Weill Cornell Medical College and The Methodist Hospital, Houston, Texas.
Retina. 2014 Jan;34(1):48-54. doi: 10.1097/IAE.0b013e3182965743.
To compare the sensitivity of commonly used time-domain (TD-OCT) and spectral-domain optical coherence tomography platforms and scanning modalities in the management of neovascular age-related macular degeneration in a population with a high prevalence of exudative disease activity.
Fifty consecutive patients within the prospective SAVE (Super-dose Anti-Vascular Endothelial growth factor) trial, which analyzed the utility of 2.0 mg intravitreal ranibizumab for the treatment of recalcitrant neovascular age-related macular degeneration, were enrolled in a comparison trial of 3 different optical coherence tomography (OCT) platforms. Stratus TD-OCT radial scan (Carl Zeiss Meditec, Inc) was compared with 3 Heidelberg Spectralis Heidelberg Retinal Angiograph+OCT (Heidelberg Engineering) acquisition settings (radial, 7-line raster, volumetric) and 2 Cirrus high definition (HD)-OCT (Carl Zeiss Meditec, Inc) acquisition settings (5-line raster, volumetric).
Using every imaging platform and acquisition setting, evidence of exudative disease activity was positively identified in 163 of 191 patient visits (85.3%). Intraretinal cysts were identified in 83 of 191 visits (43.5%), and subretinal fluid was identified in 116 of 191 visits (60.7%). Of these positive visits, the Stratus TD-OCT radial scanning technology demonstrated a significantly lower rate of detection (71.8%) when compared with the Spectralis HRA+OCT spectral domain scanning modalities (radial 87.1%, P < 0.001; 7-line raster 92.0%, P < 0.001; volumetric 94.5%, P < 0.001) or the Cirrus HD-OCT spectral domain scanning modalities (5-line raster 81.6%, P = 0.001; volumetric 92.0%, P < 0.001). Intraretinal cysts and subretinal fluid were identified in 83 visits (43.5%) and 116 visits (60.7%), respectively, with 36 eyes (18.8%) having fluid in both locations. No individual imaging modality demonstrated a diagnostic advantage for detecting subretinal fluid versus intraretinal cysts (e.g., Cirrus volume detected 86.7% of intraretinal cysts and 88.8% of subretinal fluid, P = 0.33).
In this neovascular age-related macular degeneration patient population, spectral-domain ocular coherence tomography was a superior diagnostic tool when compared with TD-OCT, with each spectral domain platform and acquisition setting identifying significantly more exudative disease activity. The two spectral domain platforms (Cirrus and Spectralis) were not directly compared because identical image acquisition parameters were not used. No individual imaging modality demonstrated a diagnostic advantage for detecting subretinal fluid versus intraretinal cysts.
比较在渗出性疾病活动高发人群中,常用的时域(TD-OCT)和光谱域光相干断层扫描平台和扫描模式在治疗新生血管性年龄相关性黄斑变性中的敏感性。
连续纳入了 50 例参与前瞻性 SAVE(超剂量抗血管内皮生长因子)试验的患者,该试验分析了 2.0mg 玻璃体内雷珠单抗治疗难治性新生血管性年龄相关性黄斑变性的疗效,这些患者被纳入了一项 3 种不同光学相干断层扫描(OCT)平台比较试验。Stratus TD-OCT 径向扫描(卡尔蔡司医学技术公司)与 3 种海德堡 Spectralis 海德堡视网膜血管造影+OCT(海德堡工程公司)采集设置(径向、7 线光栅、容积)和 2 种 Cirrus 高清(HD)-OCT(卡尔蔡司医学技术公司)采集设置(5 线光栅、容积)进行比较。
使用每种成像平台和采集设置,在 191 次就诊中有 163 次(85.3%)发现了渗出性疾病活动的证据。在 191 次就诊中,有 83 次(43.5%)发现了视网膜内囊肿,116 次(60.7%)发现了视网膜下积液。在这些阳性就诊中,Stratus TD-OCT 径向扫描技术的检出率明显低于 Spectralis HRA+OCT 光谱域扫描模式(径向 87.1%,P<0.001;7 线光栅 92.0%,P<0.001;容积 94.5%,P<0.001)或 Cirrus HD-OCT 光谱域扫描模式(5 线光栅 81.6%,P=0.001;容积 92.0%,P<0.001)。在 83 次就诊(43.5%)和 116 次就诊(60.7%)中发现了视网膜内囊肿和视网膜下积液,36 只眼(18.8%)同时存在这两种病变。没有任何一种成像模式在检测视网膜下积液与视网膜内囊肿方面具有诊断优势(例如,Cirrus 容积检测到 86.7%的视网膜内囊肿和 88.8%的视网膜下积液,P=0.33)。
在这例新生血管性年龄相关性黄斑变性患者人群中,与 TD-OCT 相比,光谱域眼相干断层扫描是一种更好的诊断工具,每个光谱域平台和采集设置都能更显著地识别出渗出性疾病活动。这两个光谱域平台(Cirrus 和 Spectralis)没有直接进行比较,因为没有使用相同的图像采集参数。没有任何一种成像模式在检测视网膜下积液与视网膜内囊肿方面具有诊断优势。