Centre for Research in Environmental Epidemiology (CREAL), Barcelona, Spain.
Occup Environ Med. 2013 Oct;70(10):681-7. doi: 10.1136/oemed-2012-101286. Epub 2013 Jun 17.
The adverse respiratory health effects of dampness and mould in the home have been extensively reported, but few studies have evaluated the health effects of such exposures in schools.
To assess the associations between dampness and mould in school buildings and respiratory symptoms among 6-12-year-old pupils in three European countries with different climates.
Based on information from self-reports and observations, we selected 29 primary schools with and 27 without moisture damage in Spain, the Netherlands and Finland. Information on respiratory symptoms and potential determinants was obtained using a parent-administered questionnaire among 6-12-year-old pupils. Country-specific associations between moisture damage and respiratory symptoms were evaluated using multivariable multilevel mixed effects logistic regression analysis.
Data from 9271 children were obtained. Nocturnal dry cough was consistently associated with moisture damage at school in each of the three countries: OR 1.15; 95% CI 1.00 to 1.30 with p for heterogeneity 0.54. Finnish children attending a moisture damaged school more often had wheeze (OR 1.36; CI 1.04 to 1.78), nasal symptoms (OR 1.34; CI 1.05 to 1.71) and respiratory-related school absence (OR 1.50; CI 1.10 to 2.03). No associations with these symptoms were found in the Netherlands or Spain (p for heterogeneity <0.05).
Moisture damage in schools may have adverse respiratory health effects in pupils. Finnish school children seem to be at higher risk, possibly due to quantitative and/or qualitative differences in exposure.
家庭潮湿和霉菌对呼吸健康的不利影响已被广泛报道,但很少有研究评估学校环境中此类暴露对健康的影响。
评估在三个气候不同的欧洲国家中,校舍内的潮湿和霉菌与 6-12 岁小学生呼吸道症状之间的关系。
根据自我报告和观察结果,我们选择了西班牙、荷兰和芬兰的 29 所具有和 27 所不具有潮湿损坏的小学。使用父母管理的问卷,向 6-12 岁的小学生收集呼吸道症状和潜在决定因素的信息。使用多变量多层次混合效应逻辑回归分析,评估了各国潮湿损坏与呼吸道症状之间的关联。
共获得 9271 名儿童的数据。在三个国家中,夜间干咳始终与学校的潮湿损坏相关:比值比(OR)为 1.15;95%置信区间(CI)为 1.00 至 1.30,异质性检验的 p 值为 0.54。在芬兰,就读于潮湿损坏学校的儿童更常出现喘息(OR 1.36;CI 1.04 至 1.78)、鼻部症状(OR 1.34;CI 1.05 至 1.71)和与呼吸道相关的缺课(OR 1.50;CI 1.10 至 2.03)。在荷兰或西班牙未发现这些症状与潮湿损坏之间存在关联(p 值<0.05,异质性检验)。
学校内的潮湿损坏可能对小学生的呼吸健康产生不利影响。芬兰的学童似乎面临更高的风险,这可能是由于暴露的数量和/或质量存在差异所致。