视盘与视野匹配的准确性:欧洲结构与功能评估试验(ESAFAT)。

Accuracy of matching optic discs with visual fields: the European Structure and Function Assessment Trial (ESAFAT).

机构信息

Glaucoma Service, Rotterdam Eye Hospital, Rotterdam, The Netherlands; Rotterdam Ophthalmic Institute, Rotterdam Eye Hospital, Rotterdam, The Netherlands.

Glaucoma Service, Rotterdam Eye Hospital, Rotterdam, The Netherlands.

出版信息

Ophthalmology. 2013 Dec;120(12):2470-2475. doi: 10.1016/j.ophtha.2013.05.026. Epub 2013 Jun 25.

Abstract

PURPOSE

To determine the ability of ophthalmologists across Europe to match stereoscopic optic disc photographs to visual fields of varying severity.

DESIGN

Evaluation and comparison of 2 diagnostic tests.

PARTICIPANTS

A total of 109 of 260 invited ophthalmologists in 11 European countries. These had participated in the previous European Optic Disc Assessment Trial (EODAT), a trial on glaucoma diagnostic accuracy based on optic discs only.

METHODS

Each participant matched stereo optic disc photographs of 40 healthy and 48 glaucomatous eyes to a visual field chosen from 4 options per disc. The 4 presented visual fields included the corresponding one and 3 other visual fields, varying in severity. The matching accuracy and any inaccuracy per disease severity were calculated. Classification accuracy (as glaucomatous or healthy) was compared with EODAT data. Duplicate slides allowed for the assessment of intraobserver agreement.

MAIN OUTCOME MEASURES

Accuracy of matching optic discs with their corresponding visual field and of classifying them as healthy or glaucomatous; intraobserver agreement (κ).

RESULTS

The overall accuracy of ophthalmologists for correctly matching stereoscopic optic disc photographs to their visual fields was 58.7%. When incorrectly matched, the observers generally overestimated the visual field severity (P<0.001), notably in eyes with early glaucoma. The intraobserver agreement was, on average, moderate (0.52).

CONCLUSIONS

European ophthalmologists correctly matched stereoscopic optic disc photographs to their corresponding visual field in only approximately 59% of cases. In most mismatches, the clinicians overestimated the visual field damage.

摘要

目的

确定欧洲眼科医生将立体视盘照片与不同严重程度的视野相匹配的能力。

设计

评估和比较 2 种诊断测试。

参与者

来自 11 个欧洲国家的 260 名受邀眼科医生中的 109 名。他们曾参加过之前的欧洲视盘评估试验(EODAT),这是一项仅基于视盘的青光眼诊断准确性试验。

方法

每位参与者将 40 张健康眼和 48 张青光眼眼的立体视盘照片与从每张视盘选择的 4 个选项中的一个视野相匹配。呈现的 4 个视野包括相应的一个和另外 3 个视野,严重程度不同。计算了每种疾病严重程度的匹配准确性和任何不准确性。与 EODAT 数据比较分类准确性(是否为青光眼或健康)。重复幻灯片允许评估观察者内的一致性。

主要观察结果

将视盘与其相应的视野相匹配的准确性,以及将其分类为健康或青光眼的准确性;观察者内一致性(κ)。

结果

眼科医生正确将立体视盘照片与视野相匹配的总体准确性为 58.7%。当匹配不正确时,观察者通常会高估视野的严重程度(P<0.001),尤其是在早期青光眼的眼中。观察者内一致性平均为中度(0.52)。

结论

欧洲眼科医生正确将立体视盘照片与其相应的视野相匹配的情况仅约为 59%。在大多数不匹配的情况下,临床医生高估了视野损伤。