Department of Physiology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia.
Eur Arch Otorhinolaryngol. 2014 Jun;271(6):1463-70. doi: 10.1007/s00405-013-2612-z. Epub 2013 Jun 28.
Although sound exposure from personal listening devices (PLDs) could potentially lead to noise-induced hearing loss (NIHL), the actual hearing risk associated with the use of these devices is still unclear. In this study, early hearing effects related to PLD usage were evaluated in 35 young adult PLD users (listening for >1 h/day, at >50% of the maximum volume setting of their devices) and their age- and sex-matched controls using a combination of conventional and extended high-frequency audiometry as well as transient-evoked otoacoustic emission (TEOAE) and distortion product of otoacoustic emission (DPOAE) measurements. The mean listening duration of the PLD users was 2.7 ± 1.0 h/day while their estimated average listening volume was 81.3 ± 9.0 dBA (free-field corrected). Typical signs of NIHL were not detected in the audiogram of PLD users and their audiometric thresholds at most of the conventional test frequencies (0.25-8 kHz) were comparable with those obtained from controls. However, compared with the controls, mean hearing thresholds of PLD users at many of the extended high-frequencies (9-16 kHz) were significantly higher. In addition, TEOAE and DPOAE amplitudes in users were reduced compared with controls. The deterioration of extended high-frequency thresholds and the decrease in DPOAE amplitudes were more evident in the users' right ears. These results indicate the presence of an early stage of hearing damage in the PLD user group. Preventive steps should be taken as the initial hearing damage in these users could eventually progress into permanent NIHL after many years of PLD use.
尽管个人听力设备(PLD)产生的声音暴露可能导致噪声性听力损失(NIHL),但与这些设备使用相关的实际听力风险仍不清楚。在这项研究中,通过常规和扩展高频测听以及瞬态诱发耳声发射(TEOAE)和畸变产物耳声发射(DPOAE)测量,评估了 35 名年轻成年 PLD 用户(每天听 >1 小时,设备最大音量设置的 >50%)及其年龄和性别匹配的对照组使用 PLD 与听力相关的早期效应。PLD 用户的平均听时长为 2.7 ± 1.0 小时/天,而他们的平均听音量估计为 81.3 ± 9.0 dBA(自由场校正)。在 PLD 用户的听力图中未发现典型的 NIHL 迹象,他们在大多数常规测试频率(0.25-8 kHz)的听力阈值与对照组相当。然而,与对照组相比,PLD 用户在许多扩展高频(9-16 kHz)的平均听力阈值明显更高。此外,与对照组相比,用户的 TEOAE 和 DPOAE 幅度降低。扩展高频阈值的恶化和 DPOAE 幅度的降低在用户的右耳更为明显。这些结果表明 PLD 用户组存在早期听力损伤。应采取预防措施,因为这些用户的初始听力损伤在多年使用 PLD 后可能最终发展为永久性 NIHL。