Prade V, Parrau G, Seguin P, Champin J, Alix T
Service de chirurgie maxillo-faciale et plastique, hôpital Nord, CHU de Saint-Étienne, 42055 Saint-Étienne cedex 2, France; Laboratoire de physiologie de l'exercice, EA 4338, université Jean-Monnet, 42023 Saint-Étienne cedex 2, France.
Rev Stomatol Chir Maxillofac Chir Orale. 2013 Nov;114(5):299-303. doi: 10.1016/j.revsto.2013.05.010. Epub 2013 Jul 12.
The major complications of free flap surgery are anastomotic obstructions. The coupler, mechanical anastomosis using a double ring eversion system, yields higher venous patency rates than sutured anastomoses, and requires less operating time. We present our initial experience with this coupler in free flap surgery.
We conducted this retrospective study between November 2011 and June 2012. We focused on complications having occurred in the first 10 patients having undergone free flap reconstruction (11 flaps) with end-to-end venous anastomosis using this coupler. Five flaps were used to fill cervico-facial defects in carcinologic surgery: one for mandibular osteoradionecrosis, one for cranioplasty coverage, one for cranial base reconstruction, two for skin defects in lower limb (heel, leg). One was an antebrachial radial flap, four anterolateral thigh flaps, five fibular flaps, and one latissimus dorsi flap. Fifteen veins were anastomosed. The diameters of the couplers used were 2.5 mm (3/15), 3 mm (6/15), and 3.5 mm (6/15).
There were no venous complications. One flap failed because of arterial ischemia.
The coupler is a fast and reliable alternative to usual sutures in free flap reconstructions, for head and neck as well as for limbs.
游离皮瓣手术的主要并发症是吻合口梗阻。使用双环外翻系统进行机械吻合的吻合器,其静脉通畅率高于缝合吻合,且所需手术时间更短。我们在此介绍我们在游离皮瓣手术中使用这种吻合器的初步经验。
我们在2011年11月至2012年6月期间进行了这项回顾性研究。我们重点关注了前10例使用这种吻合器进行端端静脉吻合的游离皮瓣重建患者(11个皮瓣)所发生的并发症。5个皮瓣用于肿瘤手术中的颈面部缺损修复:1个用于下颌骨放射性坏死,1个用于颅骨成形术覆盖,1个用于颅底重建,2个用于下肢皮肤缺损(足跟、小腿)。1个是前臂桡侧皮瓣,4个是股前外侧皮瓣,5个是腓骨皮瓣,1个是背阔肌皮瓣。共吻合了15条静脉。所使用吻合器的直径分别为2.5毫米(3/15)、3毫米(6/15)和3.5毫米(6/15)。
未发生静脉并发症。1个皮瓣因动脉缺血而失败。
在游离皮瓣重建手术中,无论是用于头颈部还是四肢,吻合器都是一种比传统缝线更快且可靠的选择。