Appl Spectrosc. 2013 Aug;67(8):841-5. doi: 10.1366/12-06915.
An analytical methodology is proposed based on constant ratio and absorbance correction methods to quantify sodium carbonate, Na₂CO₃ (1450 cm⁻¹), and sodium bicarbonate, NaHCO₃ (1000 cm⁻¹, 1923 cm⁻¹), in solid mixtures using Fourier transform infrared (FT-IR) spectroscopy. Potassium ferricyanide, K₃Fe(CN)₆ (2117cm⁻¹), was used as an internal standard to get characteristic parameters. NaHCO₃ was quantified using the constant ratio method. Spectral interference of NaHCO₃ in Na₂CO₃ (1450 cm⁻¹) was corrected using the absorbance correction method. The corrected absorbance was successfully applied to quantify Na₂CO₃ (1450 cm⁻¹) in the mixture using the constant ratio method. The results obtained for simulated samples were satisfactory (relative standard deviation less than 7%) for all samples.
本文提出了一种基于恒比和吸光度校正方法的分析方法,利用傅里叶变换红外(FT-IR)光谱法定量测定固体混合物中的碳酸钠(1450cm⁻¹)和碳酸氢钠(1000cm⁻¹、1923cm⁻¹)。六氰合铁酸钾(K₃Fe(CN)₆,2117cm⁻¹)用作内标以获得特征参数。利用恒比法对 NaHCO₃进行定量分析。利用吸光度校正法校正 Na₂CO₃(1450cm⁻¹)中 NaHCO₃的光谱干扰。校正后的吸光度成功应用于恒比法定量测定混合物中的 Na₂CO₃(1450cm⁻¹)。模拟样品的结果令人满意(所有样品的相对标准偏差均小于 7%)。