OBJECTIVE

Patients with a ventriculoperitoneal shunt for the management of hydrocephalus often undergo multiple head CT examinations for assessment of shunt malfunction. The purpose of this study was to evaluate whether a limited three-slice CT protocol would consistently provide adequate information for the diagnosis of shunt malfunction with a decrease in effective dose.

MATERIALS AND METHODS

The study group included 231 unenhanced head CT examinations performed on 128 patients with shunts for hydrocephalus. The original contiguous CT images were reviewed retrospectively. A theoretic limited three-slice study was then created from the original complete CT study and separately reviewed. This limited three-slice study was created by using the lateral topographic image to select three axial locations as follows: midpoint between foramen magnum and vertex, top of the mastoid air cells, and orbital roof. The limited study was graded for parameters of image adequacy with the original full protocol study as the reference standard.

RESULTS

Twenty-four of the 231 (10.4%) full studies had findings consistent with shunt failure; all 231 studies would have been correctly categorized with the limited three-slice protocol. The sensitivity of three-slice CT for identifying the ventricular system was 91.6% and for identifying the catheter tip, 93.5%. Limited-slice CT examination would have resulted in greater than 90% mean dose reduction in both adult and pediatric populations.

CONCLUSION

Unenhanced head CT with a limited-slice protocol provides adequate diagnostic information for the diagnosis of shunt malfunction with a greater than 90% reduction in effective dose.

摘要

目的

患有脑室腹腔分流术以治疗脑积水的患者通常需要多次进行头部 CT 检查以评估分流器故障。本研究旨在评估有限的三切片 CT 方案是否可以通过降低有效剂量来持续提供足够的信息以诊断分流器故障。

材料和方法

研究组包括 128 例脑积水患者进行的 231 次未增强头部 CT 检查。回顾性分析原始连续 CT 图像。然后,从原始完整 CT 研究中创建一个理论上的有限三切片研究,并单独进行回顾。该有限三切片研究是通过使用侧位地形图选择三个轴向位置来创建的,如下所示:枕骨大孔和顶点之间的中点、乳突气房顶部和眶顶。使用原始完整方案研究作为参考标准,对有限研究进行图像充分性参数分级。

结果

231 次完整研究中有 24 次(10.4%)发现与分流器故障一致;所有 231 次研究都可以通过有限的三切片方案正确分类。三切片 CT 对识别脑室系统的敏感性为 91.6%,对识别导管尖端的敏感性为 93.5%。在成人和儿科人群中,有限切片 CT 检查的平均剂量降低均大于 90%。

结论

采用有限切片方案的非增强性头部 CT 可提供足够的诊断信息,以诊断分流器故障,并可将有效剂量降低 90%以上。