Department of Internal Medicine and Cardiology (Kitada), Osaka City University School of Medicine, Osaka, Japan.
Clin Cardiol. 2013 Oct;36(10):603-10. doi: 10.1002/clc.22171. Epub 2013 Jul 24.
The recently introduced pocket-sized portable transthoracic echocardiography (pTTE) is accurate for measurement of cardiac chamber size and function as well as for assessment of valvular regurgitation. This study aimed to compare the diagnostic accuracy of the pocket-sized pTTE with the standard TTE (sTTE) and assess its cost-effectiveness.
The use of pocket-sized pTTE, as an initial screening tool, may be feasible, accurate and cost-effective in the diagnostic strategy of cardiac abnormalities.
The study subjects were 200 patients scheduled for sTTE and an electrocardiogram (ECG). Each patient underwent pTTE examination with the Vscan (GE Medical Systems, Milwaukee, WI) immediately after sTTE. The findings of pTTE and the ECG were compared with the results of sTTE. Cost-effectiveness was calculated.
There was a strong agreement in the detection of abnormal findings between pTTE and sTTE (agreement = 90%), whereas the agreement between the ECG and sTTE was 65%. When pTTE or the ECG was used as an initial screening tool prior to sTTE, similar cost reduction was obtained (approximately 30%) by reducing the number of referrals for sTTE. However, the negative predictive value of a diagnostic strategy with pTTE (92%) was superior to that with an ECG (67%).
This study demonstrates that the pocket-sized pTTE provides accurate detection of cardiac structural and functional abnormalities beyond the ECG. In addition, the use of pTTE as an initial screening tool prior to sTTE is cost-effective, suggesting that the pocket-sized pTTE is poised to alter the current diagnostic strategy in clinical practice.
最近推出的袖珍式便携式经胸超声心动图(pTTE)在测量心腔大小和功能以及评估瓣膜反流方面具有较高的准确性。本研究旨在比较袖珍式 pTTE 与标准 TTE(sTTE)的诊断准确性,并评估其成本效益。
袖珍式 pTTE 作为初始筛查工具,在心脏异常的诊断策略中具有可行性、准确性和成本效益。
本研究对象为 200 名计划进行 sTTE 和心电图(ECG)检查的患者。每位患者在 sTTE 后立即接受 Vscan(GE Medical Systems,Milwaukee,WI)的 pTTE 检查。比较 pTTE 和 ECG 的检查结果与 sTTE 的结果。计算成本效益。
pTTE 和 sTTE 在异常发现的检测方面具有很强的一致性(一致性=90%),而 ECG 和 sTTE 之间的一致性为 65%。当 pTTE 或 ECG 作为 sTTE 之前的初始筛查工具时,通过减少 sTTE 的转诊数量,可获得类似的成本降低(约 30%)。然而,pTTE 诊断策略的阴性预测值(92%)优于 ECG(67%)。
本研究表明,袖珍式 pTTE 能够准确检测心电图以外的心脏结构和功能异常。此外,在进行 sTTE 之前使用 pTTE 作为初始筛查工具具有成本效益,这表明袖珍式 pTTE 有望改变当前的临床实践诊断策略。