Suppr超能文献

膝关节软骨中T1ρ与T2定量的同步采集:重复性与日变化

Simultaneous acquisition of T1ρ and T2 quantification in knee cartilage: repeatability and diurnal variation.

作者信息

Li Xiaojuan, Wyatt Cory, Rivoire Julien, Han Eric, Chen Weitian, Schooler Joseph, Liang Fei, Shet Keerthi, Souza Richard, Majumdar Sharmila

机构信息

Musculo-skeletal Quantitative Imaging Research (MQIR), Department of Radiology, University of California, San Francisco (UCSF), San Francisco, California, USA.

出版信息

J Magn Reson Imaging. 2014 May;39(5):1287-93. doi: 10.1002/jmri.24253. Epub 2013 Jul 29.

Abstract

PURPOSE

To develop a robust sequence that combines T1ρ and T2 quantifications and to examine the in vivo repeatability and diurnal variation of T1ρ and T2 quantifications in knee cartilage.

MATERIALS AND METHODS

Six healthy volunteers were scanned in the morning and afternoon on 2 days using a combined T1ρ and T2 quantification sequence developed in this study. Repeatability of T1ρ and T2 quantification was estimated using root-mean-square coefficients-of-variation (RMS-CV). T1ρ and T2 values from morning scans were compared to those from afternoon scans using paired t-tests.

RESULTS

The overall RMS-CV of in vivo T1ρ and T2 quantification was 5.3% and 5.2%, respectively. The RMS-CV of am scans was 4.2% and 5.0% while the RMS-CV of pm scans was 6.0% and 6.3% for T1ρ and T2 , respectively. No significant difference was found between T1ρ or T2 values in the morning and in the afternoon.

CONCLUSION

A sequence that combines T1ρ and T2 quantification with scan time less than 10 minutes and is robust to B0 and B1 inhomogeneity was developed with excellent repeatability. For a cohort with low-level daily activity, although no significant diurnal variation of cartilage MR relaxation times was observed, the afternoon scans had inferior repeatability compared to morning scans.

摘要

目的

开发一种结合T1ρ和T2定量的可靠序列,并研究膝关节软骨中T1ρ和T2定量的体内重复性和日变化。

材料与方法

使用本研究开发的T1ρ和T2联合定量序列,在2天的上午和下午对6名健康志愿者进行扫描。使用均方根变异系数(RMS-CV)评估T1ρ和T2定量的重复性。使用配对t检验比较上午扫描和下午扫描的T1ρ和T2值。

结果

体内T1ρ和T2定量的总体RMS-CV分别为5.3%和5.2%。上午扫描的RMS-CV,T1ρ为4.2%,T2为5.0%;下午扫描的RMS-CV,T1ρ为6.0%,T2为6.3%。上午和下午的T1ρ或T2值之间未发现显著差异。

结论

开发了一种结合T1ρ和T2定量的序列,扫描时间少于10分钟,对B0和B1不均匀性具有鲁棒性,且重复性良好。对于日常活动水平较低的队列,尽管未观察到软骨MR弛豫时间有显著的日变化,但下午扫描的重复性低于上午扫描。