Suppr超能文献

温度对含额外光引发剂的复合树脂质量和颜色稳定性的影响。

Effect of temperature on the mass and color stability of additional photoinitiatorcontaining composite resins.

作者信息

Kim Tae-Hyung, García-Godoy Franklin, Ko Ching-Chang, Park Jeong-Kil, Kim Hyung-Il, Kwon Yong-Hoon

机构信息

Department of Dental Materials, School of Dentistry and Medical Research Institute, Pusan National University, Mulgeum-eup, Yangsan, 626-870, Korea.

出版信息

Dent Mater J. 2013;32(4):628-36. doi: 10.4012/dmj.2013-087.

Abstract

The purpose of this study was to evaluate how the temperature affects the stability of polymerized additional photoinitiator-containing composite resins. Five resin products were light-cured using a quartz-tungsten-halogen, and single and dual emission peaks lightemitting diodes. The degree of conversion (DC) and water sorption, solubility, and color change of the specimens were evaluated after immersion in the solutions of different temperatures (4, 37, and 60ºC) for 14 days. On the top surface, the light-curing units had no significant influence on DC of the tested specimens. On the bottom surface, the influence was inconsistent. As the solution temperature increased, water sorption also consistently increased in all specimens, whereas solubility changed inconsistently. Water sorption and solubility had a high linear correlation only at low temperature solution. Color change of the specimens was similar, mostly slight, and statistically inconsistent regardless of solution temperature. The restored composite resins are needed to avoid contact with hot solutions for durable dental restoration.

摘要

本研究的目的是评估温度如何影响含额外光引发剂的聚合复合树脂的稳定性。使用石英钨卤素灯以及单发射峰和双发射峰发光二极管对五种树脂产品进行光固化。将试样浸泡在不同温度(4、37和60℃)的溶液中14天后,评估其转化率(DC)、吸水性、溶解性和颜色变化。在顶面,光固化设备对测试试样的DC没有显著影响。在底面,影响不一致。随着溶液温度升高,所有试样的吸水性也持续增加,而溶解性变化不一致。仅在低温溶液中,吸水性和溶解性具有高度线性相关性。无论溶液温度如何,试样的颜色变化相似,大多轻微,且在统计学上不一致。为了实现持久的牙齿修复,修复用复合树脂需要避免与热溶液接触。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验