Suppr超能文献

氟-18-氟脱氧葡萄糖正电子发射断层扫描在诊断糖尿病足相关性骨髓炎中的诊断效能:一项系统评价和荟萃分析

Diagnostic performance of Fluorine-18-Fluorodeoxyglucose positron emission tomography for the diagnosis of osteomyelitis related to diabetic foot: a systematic review and a meta-analysis.

作者信息

Treglia Giorgio, Sadeghi Ramin, Annunziata Salvatore, Zakavi Seyed Rasoul, Caldarella Carmelo, Muoio Barbara, Bertagna Francesco, Ceriani Luca, Giovanella Luca

机构信息

Department of Nuclear Medicine and PET/CT Center, Ente Ospedaliero Cantonale, Bellinzona, Switzerland.

出版信息

Foot (Edinb). 2013 Dec;23(4):140-8. doi: 10.1016/j.foot.2013.07.002. Epub 2013 Jul 29.

Abstract

OBJECTIVE

To systematically review and meta-analyse published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in osteomyelitis related to diabetic foot.

METHODS

A comprehensive literature search of studies on (18)F-FDG-PET and PET/CT in patients with diabetic foot was performed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) and area under the summary ROC curve of (18)F-FDG-PET and PET/CT in patients with osteomyelitis related to diabetic foot were calculated.

RESULTS

Nine studies comprising 299 patients with diabetic foot were included in the qualitative analysis (systematic review) and discussed. The quantitative analysis (meta-analysis) of four selected studies provided the following results on a per patient-based analysis: sensitivity was 74% [95% confidence interval (95%CI): 60-85%], specificity 91% (95%CI: 85-96%), LR+ 5.56 (95%CI: 2.02-15.27), LR- 0.37 (95%CI: 0.10-1.35), and DOR 16.96 (95%CI: 2.06-139.66). The area under the summary ROC curve was 0.874.

CONCLUSIONS

In patients with suspected osteomyelitis related to diabetic foot (18)F-FDG-PET and PET/CT demonstrated a high specificity, being potentially useful tools if combined with other imaging methods such as MRI. Nevertheless, the literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited.

摘要

目的

系统评价和荟萃分析已发表的关于氟-18-氟脱氧葡萄糖((18)F-FDG)正电子发射断层扫描(PET)及PET/计算机断层扫描(PET/CT)在糖尿病足相关性骨髓炎诊断效能的数据。

方法

对有关(18)F-FDG-PET及PET/CT用于糖尿病足患者的研究进行全面文献检索。计算(18)F-FDG-PET及PET/CT在糖尿病足相关性骨髓炎患者中的合并敏感度、特异度、阳性及阴性似然比(LR+和LR-)、诊断比值比(DOR)以及汇总ROC曲线下面积。

结果

定性分析(系统评价)纳入并讨论了9项包含299例糖尿病足患者的研究。对4项选定研究的定量分析(荟萃分析)在基于个体患者的分析中得出以下结果:敏感度为74%[95%置信区间(95%CI):60 - 85%],特异度为91%(95%CI:85 - 96%),LR+为5.56(95%CI:2.02 - 15.27),LR-为0.37(95%CI:0.10 - 1.35),DOR为16.96(95%CI:2.06 - 139.66)。汇总ROC曲线下面积为0.874。

结论

对于疑似糖尿病足相关性骨髓炎的患者,(18)F-FDG-PET及PET/CT显示出较高的特异度,若与其他成像方法(如MRI)联合使用可能是有用的工具。然而,专注于(18)F-FDG-PET及PET/CT在此情况下应用的文献仍然有限。