Membrane Laboratory, Department of Chemical Engineering, Anna University, Chennai, 600025, India.
Mater Sci Eng C Mater Biol Appl. 2013 Oct;33(7):3615-26. doi: 10.1016/j.msec.2013.04.043. Epub 2013 Apr 30.
Poly (ether-imide) (PEI) was carboxylated and used as the hydrophilic modification agent for the preparation of polyacrylonitrile (PAN) membranes. Membranes were prepared with different blend compositions of PAN and CPEI by diffusion induced precipitation. The modified membranes were characterized by thermo gravimetric analysis (TGA), mechanical analysis, scanning electron microscopy (SEM) and contact angle measurement to understand the influence of CPEI on the properties of the membranes. The biocompatibility studies exhibited reduced plasma protein adsorption, platelet adhesion and thrombus formation on the modified membrane surface. The complete blood count (CBC) results of CPEI incorporated membranes showed stable CBC values and significant decrease in the complement activation were also observed. In addition to good cytocompatibility, monocytes cultured on these modified membranes exhibited improved functional profiles in 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyl tetrazolium bromide (MTT) assay. Thus it could be concluded that PAN/CPEI membranes with excellent biocompatibility can be useful for hemodialysis.
聚醚酰亚胺(PEI)被羧基化,并用作制备聚丙烯腈(PAN)膜的亲水性改性剂。通过扩散诱导沉淀,用不同的 PAN 和 CPEI 共混组成制备了膜。通过热重分析(TGA)、机械分析、扫描电子显微镜(SEM)和接触角测量对改性膜进行了表征,以了解 CPEI 对膜性能的影响。生物相容性研究表明,改性膜表面的血浆蛋白吸附、血小板黏附和血栓形成减少。CPEI 加入的膜的全血细胞计数(CBC)结果显示,CBC 值稳定,补体激活显著降低。除了良好的细胞相容性外,在这些改性膜上培养的单核细胞在 3-(4,5-二甲基噻唑-2-基)-2,5-二苯基四氮唑溴化物(MTT)测定中表现出改善的功能谱。因此,可以得出结论,具有优异生物相容性的 PAN/CPEI 膜可用于血液透析。