Suppr超能文献

液相色谱-串联质谱法同时测定大鼠尿液和粪便中的曲安西龙及其代谢物。

Simultaneous determination of trantinterol and its metabolites in rat urine and feces by liquid chromatography-tandem mass spectrometry.

机构信息

Department of Analytical Chemistry, School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road, Shenyang 110016, China.

出版信息

J Chromatogr B Analyt Technol Biomed Life Sci. 2013 Sep 1;934:89-96. doi: 10.1016/j.jchromb.2013.06.033. Epub 2013 Jul 5.

Abstract

A highly selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of trantinterol (SPFF) and its major metabolites for the first time. The analytes were extracted from rat urine and feces samples by liquid-liquid extraction (LLE) and determined in multiple reaction monitoring (MRM) mode with clenbuterol as the internal standard. Chromatographic separation was achieved on a Venusil ASB C8 column (2.1mm×100mm, 3μm), with the mobile phase consisted of methanol-0.2% formic acid (30:70, v/v) at the flow rate of 0.2mL/min. Each sample was chromatographed within 5min. This method has a lower limit of quantification (LLOQ) of 0.450, 1.05, 1.35, 0.904 and 1.36ng/mL for trantinterol (SPFF), arylhydroxylamine trantinterol (N-OH-SPFF), tert-butyl hydroxylated trantinterol (Tert-OH-SPFF), 1-carbonyl trantinterol (SPFF-COOH) and 3-methyl sulfone-dechloro-trantinterol (SPFF-SO2CH3) in rat urine, and 0.450, 1.35 and 0.904ng/mL for SPFF, Tert-OH-SPFF and SPFF-COOH in rat feces, respectively. The linear correlation coefficients were greater than 0.990. The intra- and inter-day precision (relative standard deviation, RSD) values were below 15% and the accuracy (relative error, RE) was -9.9% to 11% at three quality control levels. The method has been successfully applied to the excretion study following an oral administration of 1mg/kg trantinterol to rats.

摘要

建立了一种同时测定曲安奈德(SPFF)及其主要代谢物的高选择性和高灵敏度的液相色谱-串联质谱(LC-MS/MS)方法。通过液液萃取(LLE)从大鼠尿样和粪样中提取分析物,以内标克仑特罗进行多反应监测(MRM)模式测定。色谱分离在 Venusil ASB C8 柱(2.1mm×100mm,3μm)上进行,流动相为甲醇-0.2%甲酸(30:70,v/v),流速为 0.2mL/min。每个样品的色谱分析时间均在 5min 以内。该方法在大鼠尿样中曲安奈德(SPFF)、芳基羟胺曲安奈德(N-OH-SPFF)、叔丁基羟化曲安奈德(Tert-OH-SPFF)、1-羰基曲安奈德(SPFF-COOH)和 3-甲基亚砜去氯曲安奈德(SPFF-SO2CH3)的定量下限(LLOQ)分别为 0.450、1.05、1.35、0.904 和 1.36ng/mL,在大鼠粪样中 SPFF、Tert-OH-SPFF 和 SPFF-COOH 的定量下限分别为 0.450、1.35 和 0.904ng/mL。线性相关系数均大于 0.990。在三个质控水平下,日内和日间精密度(相对标准偏差,RSD)均低于 15%,准确度(相对误差,RE)为-9.9%至 11%。该方法已成功应用于大鼠口服 1mg/kg 曲安奈德后的排泄研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验