Naseri Mandana, Kangarlou Ali, Khavid Atefeh, Goodini Mostafa
Iranian Center for Endodontic Research, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran ; Department of Endodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Iran Endod J. 2013 Summer;8(3):89-93. Epub 2013 Aug 1.
One of the key factors in successful endodontic therapy is to adequately fill the root canals. The aim of this in vitro study was to compare the quality of four different root canal obturation techniques: cold lateral condensation (CLC), warm vertical condensation (WVC), Obtura II (OII) and Gutta Flow (GF) by using micro-computed tomography (micro CT).
A total of 20 extracted maxillary first molars prepared with ProTaper files, were randomly divided into four groups. Micro CT was used to measure the internal volume of root canals. Following application of AH26 sealer to canal obturation, new micro-CT images were taken and the volume percentage (VP) of voids, gutta-percha and sealer at different levels were calculated with CT software. Data was statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests.
The highest percentage of filling material was observed in GF group followed by OII with no statistically significant difference (P>0.05). These two groups had a significantly more acceptable filling than WVC and CLC groups (P<0.05). Voids were detected in all samples. There was a significant difference between the highest and the lowest percentage of voids in CLC (19.6%) and GF groups (6.7%), respectively. In the apical third, CLC and OII showed the highest and the lowest percentage of voids (5.5% and 2.6%) and the lowest and highest percentage of gutta-percha (76.52% and 94.26%), respectively. These differences were statistically significant (P<0.05).
None of the root canal filled teeth were gap-free. GF and CLC techniques showed the highest and lowest VP of obturation materials, respectively.
成功进行牙髓治疗的关键因素之一是充分充填根管。本体外研究的目的是使用微型计算机断层扫描(显微CT)比较四种不同根管充填技术的质量:冷侧向加压充填(CLC)、热垂直加压充填(WVC)、Obtura II(OII)和Gutta Flow(GF)。
总共20颗用ProTaper锉预备的上颌第一恒磨牙被随机分为四组。使用显微CT测量根管的内部容积。在根管充填应用AH26封闭剂后,拍摄新的显微CT图像,并用CT软件计算不同水平处的空隙、牙胶和封闭剂的体积百分比(VP)。数据采用Kruskal-Wallis检验和Mann-Whitney U检验进行统计学分析。
GF组观察到的充填材料百分比最高,其次是OII组,两组之间无统计学显著差异(P>0.05)。这两组的充填效果明显优于WVC组和CLC组(P<0.05)。所有样本中均检测到空隙。CLC组(19.6%)和GF组(6.7%)的空隙百分比最高值与最低值之间存在显著差异。在根尖三分之一处,CLC组和OII组分别显示出最高和最低的空隙百分比(5.5%和2.6%)以及最低和最高的牙胶百分比(76.52%和94.26%)。这些差异具有统计学意义(P<0.05)。
根管充填后的牙齿均未完全无间隙。GF技术和CLC技术分别显示出充填材料的最高和最低体积百分比。