Department of Imaging and Interventional Radiology, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong, China,
Skeletal Radiol. 2013 Nov;42(11):1549-54. doi: 10.1007/s00256-013-1705-5. Epub 2013 Aug 18.
An accurate in vivo method of measuring dimensions of the anteromedial (AM) and posterolateral (PL) anterior cruciate ligament (ACL) bundles has not been established. The purpose of this study was to measure each individual bundle using double oblique axial MR imaging of the ACL, to compare this with cadaveric measurements, and to investigate the range of measurements seen in normal subjects.
In five cadaveric knees, measurements obtained of the proximal, middle, and distal segments of each ACL bundle from double oblique axial MR images were compared with direct measurements following anatomical dissection. Thereafter, the size of both bundles from 24 normal knees was measured using an identical MR technique. Inter-observer variation was calculated using intraclass correlation.
ACL bundle measurement in the cadaveric knees had a strong correlation (r = 0.93) with measurements obtained following anatomical dissection. No significant difference existed between measurements obtained from cadaveric knees and living normal subjects (p > 0.05). Interobserver correlation for MR measurements was excellent (R = 0.92-0.93). Overall, the long and short axis of the AM bundle were significantly larger than those of the PL bundle (p < 0.05). Also, men showed significantly larger AM and PL bundles than women (p < 0.05). Bundle size was not related to age or knee dominance.
The individual ACL bundles can be accurately measured on double oblique axial MR imaging. The AM bundle is larger in caliber than the PL bundle. Both bundles are larger in men than in women and there is no significant side-to side difference.
尚未建立一种准确的活体测量前内侧(AM)和后外侧(PL)前交叉韧带(ACL)束尺寸的方法。本研究的目的是使用 ACL 的双斜轴 MR 成像测量每个单独的束,并将其与尸体测量进行比较,并研究正常受试者的测量范围。
在 5 个尸体膝关节中,比较了双斜轴 MR 图像上获得的 ACL 各束近端、中段和远端的测量值与解剖后直接测量值。此后,使用相同的 MR 技术测量了 24 个正常膝关节的两个束的大小。使用组内相关系数计算观察者间变异性。
尸体膝关节 ACL 束的测量值与解剖后获得的测量值具有很强的相关性(r=0.93)。尸体膝关节和正常活体受试者的测量值之间无显着差异(p>0.05)。MR 测量的观察者间相关性非常好(R=0.92-0.93)。总体而言,AM 束的长轴和短轴明显大于 PL 束(p<0.05)。此外,男性的 AM 和 PL 束明显大于女性(p<0.05)。束的大小与年龄或膝关节优势无关。
在双斜轴 MR 成像上可以准确测量 ACL 各束。AM 束的口径大于 PL 束。男性的 AM 和 PL 束均大于女性,且左右侧无显着差异。