J Cataract Refract Surg. 2013 Nov;39(11):1675-81. doi: 10.1016/j.jcrs.2013.04.039. Epub 2013 Aug 22.
To analyze the changes in incision sizes after implantation of a toric intraocular lens (IOL) using 2 methods.
Department of Ophthalmology, Clínica Universidad de Navarra, Pamplona, Spain.
Prospective case series.
Coaxial phacoemulsification and IOL implantation through a 2.2 mm clear corneal incision using a cartridge injector were performed. Wound-assisted or cartridge-insertion techniques were used to implant the IOLs. The results were analyzed according to IOL spherical and cylindrical powers. Corneal hysteresis (CH) and the corneal resistance factor (CRF) were measured and evaluated based on the changes in incision size.
Incision size increased in 30 (41.7%) of 72 eyes in the wound-assisted group and 71 (98.6%) of 72 eyes in the cartridge-insertion group. The mean incision size after IOL implantation was 2.27 mm ± 0.06 (SD) and 2.37 ± 0.05 mm, respectively (P<.01). The final incision size and IOL spherical power in the wound-assisted technique group (P=.02) and the cartridge-insertion technique group (P=.03) were correlated significantly; IOL toricity was not (P=.19 and P=.28, respectively). The CH and CRF values were not correlated with the final incision size.
The final incision size and the changes in incision size after IOL implantation were greater with the cartridge-insertion technique than with the wound-assisted technique. The increase was related to IOL spherical power in both groups but not to IOL toricity. Corneal biomechanical properties were not correlated with the final incision size.
分析两种方法植入散光型人工晶状体(IOL)后切口大小的变化。
西班牙纳瓦拉大学临床眼科诊所。
前瞻性病例系列。
采用同轴超声乳化术,通过 2.2mm 透明角膜切口,使用卡式注射器植入 IOL。采用切口辅助或卡式插入技术植入 IOL。根据 IOL 球镜和柱镜度数分析结果。测量角膜滞后(CH)和角膜阻力因子(CRF),根据切口大小的变化进行评估。
在切口辅助组的 72 只眼中,有 30 只(41.7%)和在卡式插入组的 72 只眼中,有 71 只(98.6%)切口增大。IOL 植入后的平均切口大小分别为 2.27mm±0.06(SD)和 2.37mm±0.05mm(P<.01)。在切口辅助技术组(P=.02)和卡式插入技术组(P=.03)中,最终切口大小和 IOL 球镜度数呈显著相关;而 IOL 散光度数与最终切口大小无显著相关性(分别为 P=.19 和 P=.28)。CH 和 CRF 值与最终切口大小无相关性。
与切口辅助技术相比,卡式插入技术的最终切口大小和 IOL 植入后的切口大小变化更大。两组的增加都与 IOL 球镜度数有关,但与 IOL 散光度数无关。角膜生物力学特性与最终切口大小无关。