Suppr超能文献

氧气注入速率、呼吸频率和潮气量对连接肺模型的尸体犬头部吸入氧分数的影响。

Effects of oxygen insufflation rate, respiratory rate, and tidal volume on fraction of inspired oxygen in cadaveric canine heads attached to a lung model.

作者信息

Zimmerman Melina E, Hodgson David S, Bello Nora M

机构信息

Department of Clinical Sciences, Kansas State University Veterinary Health Center, Kansas State University, Manhattan, KS 66506, USA.

出版信息

Am J Vet Res. 2013 Sep;74(9):1247-51. doi: 10.2460/ajvr.74.9.1247.

Abstract

OBJECTIVE

To assess the effects of oxygen insufflation rate, respiratory rate, and tidal volume on fraction of inspired oxygen (Fio2) in cadaveric canine heads attached to a lung model.

SAMPLE

16 heads of canine cadavers.

PROCEDURES

Each cadaver head was instrumented with a nasal insufflation catheter through which oxygen was delivered. The trachea was attached to a sample collection port connected by means of corrugated tubing to a lung model. Eight treatment combinations that varied in respiratory rate (10 or 20 breaths/min), tidal volume (10 or 15 mL/kg), and oxygen insufflation rate (50 or 100 mL/kg/min) were applied to each head in a replicated Latin square design. Gas samples were manually collected, and inspired oxygen concentrations were analyzed. The Fio2 and end-tidal CO2 concentration were determined and compared among sample groups.

RESULTS

Estimated least squares mean Fio2 for various treatment combinations ranged from 32.2% to 60.6%. The Fio2 was significantly increased at the higher insufflation rate (estimated marginal least squares mean, 48.7% vs 38.6% for 100 and 50 mL/kg/min, respectively), lower respiratory rate (48.9% vs 38.3% for 10 and 20 breaths/min, respectively), and smaller tidal volume (46.8% vs 40.0% for 10 and 15 mL/kg, respectively).

CONCLUSIONS AND CLINICAL RELEVANCE

-Fio2 in the model was affected by oxygen insufflation rate, respiratory rate, and tidal volume. This information may potentially help clinicians interpret results of blood gas analysis and manage canine patients receiving oxygen insufflation via a nasal catheter.

摘要

目的

评估在连接肺模型的犬类尸体头部中,氧气吹入速率、呼吸频率和潮气量对吸入氧分数(Fio2)的影响。

样本

16个犬类尸体头部。

步骤

每个尸体头部都安装了一根鼻内吹入导管,通过该导管输送氧气。气管连接到一个样本采集端口,该端口通过波纹管连接到一个肺模型。采用重复拉丁方设计,对每个头部应用八种呼吸频率(10或20次/分钟)、潮气量(10或15毫升/千克)和氧气吹入速率(50或100毫升/千克/分钟)各不相同的治疗组合。手动采集气体样本,并分析吸入氧浓度。测定并比较各样本组的Fio2和呼气末二氧化碳浓度。

结果

各种治疗组合的估计最小二乘均值Fio2范围为32.2%至60.6%。在较高的吹入速率下(估计边际最小二乘均值,100和50毫升/千克/分钟时分别为48.7%和38.6%)、较低的呼吸频率下(10和20次/分钟时分别为48.9%和38.3%)以及较小的潮气量下(10和15毫升/千克时分别为46.8%和40.0%),Fio2显著升高。

结论及临床意义

模型中的Fio2受氧气吹入速率、呼吸频率和潮气量的影响。这些信息可能有助于临床医生解读血气分析结果,并管理通过鼻导管接受氧气吹入的犬类患者。