Badea Alexandru Florin, Tamas Szora Attila, Ciuleanu Elisabeta, Chioreanu Ioana, Băciuţ Grigore, Lupşor Platon Monica, Badea Radu
1Department of Maxillofacial Surgery, Iuliu Haţeganu University of Medicine and pharmacy, Cluj Napoca, România.
Med Ultrason. 2013 Sep;15(3):173-9. doi: 10.11152/mu.2013.2066.153.afb1ats2.
Evaluation of Acoustic Radiation Force Impulse Imaging (ARFI) elastography performance in predicting the elasticity of the submandibular glands in normal situations and after radiation therapy.
A number of 54 normal submandibular glands from 27 voluntary subjects and 33 pathological submandibular glands (radiation submaxillities) from 18 patients who had undergone radiation therapy for various cervical and facial oncological conditions were included in study. All the patients had undergone a B mode ultrasonography (Tissue Harmonic Imaging, 8-14 MHz) while the submandibular volume was determined and subsequently an ARFI examination while the shear wave velocity (SWV) was measured (in the central, peripheral and subcapsular areas, with the results expressed in m/s).
In the volunteers' group the mean value of the SWV of the left submandibular gland was 1.68 ± 0.46 m/s, determined in the centre of the gland, 1.88 ± 0.4 m/s in the periphery (corresponding to the subcapsular parenchyma) and the SWV of the right submandibular gland was 1.74 ± 0.35 m/s (centrally) and 1.84 ± 0.43 m/s in the periphery. The mean value of all measurements was 1.82 ± 0.41 m/s. The mean volume of the glands was 7.97 ± 2.63 cm3. In the group of patients who had underwent radiation therapy (at least 35Gy), the mean value of the SWV was 2.24 ± 0.49 m/s centrally and 2.1 ± 0.58 m/s in the periphery on the left and 1.99 ± 0.5 m/s centrally and 2.21 ± 0.52 m/s in the periphery on the right. The mean value of all the measurements was 2.13 ± 0.52 m/s and the mean volume of the gland was 5.95 ± 4.16 cm3.
Elastography using ARFI technique is a valid examination in the evaluation of the normal and pathological submandibular gland stiffness. The values of the shear wave velocities that correspond to a normal stiffness, determined through the ARFI technique, are similar in the two glands. After cervical and facial radiation therapy the values of the SWV are increased, indicating a change in the consistency of the gland thus implying a structural transformation. The ARFI technique can be used in the evaluation of the salivary glands pathology.
评估声辐射力脉冲成像(ARFI)弹性成像在预测正常情况下及放射治疗后颌下腺弹性方面的性能。
本研究纳入了27名志愿者的54个正常颌下腺以及18名因各种头颈面部肿瘤疾病接受放射治疗的患者的33个病理性颌下腺(放射性颌下腺炎)。所有患者均接受了B型超声检查(组织谐波成像,8 - 14MHz)以测定颌下腺体积,随后进行ARFI检查以测量剪切波速度(SWV)(在腺体中央、周边和包膜下区域测量,结果以m/s表示)。
在志愿者组中,左侧颌下腺中央的SWV平均值为1.68±0.46m/s,周边(对应包膜下实质)为1.88±0.4m/s;右侧颌下腺中央的SWV平均值为1.74±0.35m/s,周边为1.84±0.43m/s。所有测量值的平均值为1.82±0.41m/s。腺体的平均体积为7.97±2.63cm³。在接受放射治疗(至少35Gy)的患者组中,左侧中央SWV平均值为2.24±0.49m/s,周边为2.1±0.58m/s;右侧中央SWV平均值为1.99±0.5m/s,周边为2.21±0.52m/s。所有测量值的平均值为2.13±0.52m/s,腺体的平均体积为5.95±4.16cm³。
使用ARFI技术的弹性成像是评估正常和病理性颌下腺硬度的有效检查方法。通过ARFI技术确定的对应正常硬度的剪切波速度值在两个腺体中相似。头颈面部放射治疗后SWV值升高,表明腺体质地发生变化,意味着结构改变。ARFI技术可用于评估唾液腺病变。