AIM

To develop a method to evaluate the cutting behaviour of nickel-titanium (NiTi) coronal flaring instruments.

METHODOLOGY

BioRaCe BR0 (BR), HyFlex CM 1 (HY), ProFile OS No. 2 (PF) and ProTaper Sx (PT) instruments were used in simulated coronal flaring using a lateral action against bovine dentine blocks, at 250 and 500 rpm. Cutting efficiency was assessed by three methods: first, areas of notches produced by instruments were directly measured under a stereomicroscope. Second, dentine specimens were then analysed by surface profilometry to determine the maximum cutting depth and finally by microcomputed tomography to assess the volume of removed dentine. Data were compared using parametric tests with the significance level set at 0.05.

RESULTS

For all three methods, HY and PF were the most and the least cutting-efficient instruments, respectively (P < 0.05). Significant differences were detected between 250 and 500 rpm for HY and PT (area); for BR, HY and PT (depth); and for BR and HY (volume). There were strong positive correlations between the results obtained with those three different methods with r-values ranging from 0.81 to 0.92.

CONCLUSION

Measuring the amount of material removed in a specific time under stereomicroscopy is a simple and rational way to assess the cutting behaviour of NiTi rotary instruments in lateral action. HyFlex, manufactured with thermomechanically treated NiTi wire, was the most efficient instrument, and increased rotational speed was associated with increased cutting efficiency.

摘要

目的

开发一种评估镍钛(NiTi)冠向扩锉器械切削行为的方法。

方法

使用 BioRaCe BR0(BR)、HyFlex CM 1(HY)、ProFile OS No. 2(PF)和 ProTaper Sx(PT)器械,在侧向作用于牛牙本质块时,以 250 和 500rpm 的转速进行模拟冠向扩锉。通过三种方法评估切削效率:首先,在立体显微镜下直接测量器械产生的凹痕面积。其次,通过表面轮廓仪分析牙本质样本,以确定最大切削深度,最后通过微计算机断层扫描评估去除的牙本质体积。使用参数检验比较数据,显著性水平设为 0.05。

结果

对于所有三种方法,HY 和 PF 的切削效率最高和最低(P<0.05)。在 250 和 500rpm 时,HY 和 PT(面积)、BR、HY 和 PT(深度)以及 BR 和 HY(体积)之间存在显著差异。三种不同方法获得的结果之间存在强正相关,r 值范围为 0.81 至 0.92。

结论

在立体显微镜下测量特定时间内去除的材料量是评估 NiTi 旋转器械侧向切削行为的一种简单而合理的方法。HyFlex 采用热机械处理的 NiTi 丝制造,是最有效的器械,增加转速与切削效率的提高有关。