Santos Joana, Foley Shane, Paulo Graciano, McEntee Mark F, Rainford Louise
College of Health Technology, Polytechnic Institute of Coimbra, Coimbra, Portugal.
Radiat Prot Dosimetry. 2014;158(3):307-17. doi: 10.1093/rpd/nct226. Epub 2013 Sep 15.
The aims of this study were to investigate the frequency of Portuguese computed tomography (CT) examinations, identify protocol application and establish diagnostic reference levels (DRLs). CT departments (n=211) were surveyed nationally (June 2011-January 2012) and CT protocol information and dose data were collected, as were retrospective age-categorised paediatric CT data from three national paediatric centres. The proposed national CT DRLs (CTDIvol) for adults were 75, 18, 14, 18, 17, 36, 22, 27 and 16 mGy for head, neck, chest, abdomen, pelvis, cervical, dorsal, lumbar and joints, respectively. The levels for paediatric head and chest examinations were as follows: 48 and 2 mGy (newborns), 50 and 6 mGy (5 y olds), 70 and 6 mGy (10 y olds) and 72 and 7 mGy (15 y olds). A limited number of current paediatric protocols aligned to recommended international age categorisations. Portuguese DRLs were generally higher than European recommendations, suggesting potential for optimisation. The need for greater standardisation of age-categorised paediatric protocols was identified.
本研究的目的是调查葡萄牙计算机断层扫描(CT)检查的频率,确定协议应用情况并建立诊断参考水平(DRLs)。2011年6月至2012年1月期间在全国范围内对211个CT科室进行了调查,收集了CT协议信息和剂量数据,以及来自三个国家儿科中心的按年龄分类的儿科CT回顾性数据。建议的成人国家CT诊断参考水平(CTDIvol),头部、颈部、胸部、腹部、骨盆、颈椎、胸椎、腰椎和关节分别为75、18、14、18、17、36、22、27和16毫西弗。儿科头部和胸部检查的水平如下:新生儿为48和2毫西弗,5岁儿童为50和6毫西弗,10岁儿童为70和6毫西弗,15岁儿童为72和7毫西弗。目前符合推荐的国际年龄分类的儿科协议数量有限。葡萄牙的诊断参考水平通常高于欧洲的建议,表明存在优化的潜力。确定了对按年龄分类的儿科协议进行更大程度标准化的必要性。