Aguirre P M, Cacho J B, Folgueira L, López M, García J, Velasco A C
Servicio de Microbiología, Hospital de la Seguridad Social La Paz, Madrid, Spain.
J Clin Microbiol. 1990 Jan;28(1):148-9. doi: 10.1128/jcm.28.1.148-149.1990.
Four hundred thirty-two lactose-negative colonies isolated from human feces on stool differential agar media were flooded with one drop of MUCAP Test reagent (Biolife Italiana S.r.I., Milan, Italy) and observed under a Wood lamp for the development of a blue fluorescence over or around the colony. On the basis of manual and automated conventional tests for the screening of Salmonella spp., the MUCAP Test yielded the following results: 79 true-positives, 314 true-negatives, 35 false-positives, and 4 false-negatives (sensitivity, 95%; specificity, 90%; positive predictive value, 69%; negative predictive value, 99%). The specificity of the test performed on colonies isolated on MacConkey agar (95%) was higher than that performed on colonies isolated on SS agar (88%; P less than 0.03). The MUCAP Test is an easy, rapid, and sensitive method for the screening of colonies suspected of being Salmonella spp., reducing the number of biochemical tests needed.
将从粪便鉴别琼脂培养基上的人类粪便中分离出的432个乳糖阴性菌落,滴加一滴MUCAP检测试剂(意大利比奥life公司,米兰,意大利),并在伍德灯下观察菌落上方或周围是否出现蓝色荧光。基于用于筛选沙门氏菌属的手动和自动常规检测,MUCAP检测得出以下结果:79个真阳性、314个真阴性、35个假阳性和4个假阴性(灵敏度为95%;特异性为90%;阳性预测值为69%;阴性预测值为99%)。在麦康凯琼脂上分离的菌落上进行的检测特异性(95%)高于在SS琼脂上分离的菌落上进行的检测特异性(88%;P小于0.03)。MUCAP检测是一种简单、快速且灵敏的方法,用于筛选疑似沙门氏菌属的菌落,减少了所需的生化检测数量。