• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Contact dermatitis in hospital patients.

作者信息

Ancona A, Arévalo A, Macotela E

机构信息

National Autonomous University of Mexico, D. F.

出版信息

Dermatol Clin. 1990 Jan;8(1):95-105.

PMID:2406065
Abstract

Contact dermatitis in hospital patients resulting from diagnostic and therapeutic procedures presents various causes and clinical aspects. Antiseptics are the most frequent cause of contact dermatitis in patients undergoing surgery. Thimerosal may cause allergic sensitization mainly in patients previously exposed to contact with different sources of these mercurials, such as tinctures and preservatives in other products. Iodine-containing solutions and quaternary ammonium compounds rarely sensitize. They may cause irritation under certain circumstances, however. Adhesive tapes formulated on a rubber and colophony base are rarely found nowadays in medical adhesives; however, some tapes and skin closures have still been found to contain them. Acrylate-based adhesives sensitize less frequently. Cardiology patients may present contact dermatitis from several different sources. Electrode gels and pastes may cause allergic contact dermatitis mainly from preservatives. Modern electrocardiographic equipment does not require the use of these products, so many of these problems are now easy to avoid. Adhesive-coated pregelled foam disks for holding long-term chest contacts may cause irritant dermatitis. Transdermal drug delivery systems such as nitroglycerin disks may cause irritation attributable to the acrylic adhesives. Silicone-based adhesive disks are a good alternative in this case. Sensitization to nitroglycerin itself is rare. Dermatitis originated from implantation of pacemakers is attributable either to epoxy resin or to the metal used for the casing of the pacemaker. Changing to a different material solves the problem. In other instances, the etiology remains unclear. Dermatoses in patients with stomas constitute an important problem not only because of their frequency but also because of the multiplicity of pictures involved. Irritant dermatitis from intestinal efflux in ileostomy patients is the most frequent problem. Allergic dermatitis may originate from the ostomy device, cementing materials, or topical medicaments. Individuals receiving hemodialysis have been reported to develop widespread dermatitis, probably secondary to rubber or metal components leached out from the hemodialysis apparatus. Systemic exposure to these compounds, although not certainly proved, seems to be the explanation. Allergic dermatitis at the puncture site on arteriovenous shunts has been demonstrated to be produced by epoxy resin adhesives present in catheters. Identification of the allergen allows one to find a safe alternative for these patients who depend on this procedure to survive. Contact dermatitis in hospital patients requires a precise diagnosis. Extensive patch testing is sometimes needed for establishing the cause, which in turn provides a more accurate prognosis and a rational treatment.

摘要

相似文献

1
Contact dermatitis in hospital patients.
Dermatol Clin. 1990 Jan;8(1):95-105.
2
[Epoxy resin as a cause of contact allergic eczema].[环氧树脂作为接触性过敏性湿疹的病因]
Ned Tijdschr Geneeskd. 1989 Jul 29;133(30):1505-9.
3
Final report on the safety assessment of capsicum annuum extract, capsicum annuum fruit extract, capsicum annuum resin, capsicum annuum fruit powder, capsicum frutescens fruit, capsicum frutescens fruit extract, capsicum frutescens resin, and capsaicin.关于辣椒提取物、辣椒果实提取物、辣椒树脂、辣椒果粉、小米辣果实、小米辣果实提取物、小米辣树脂和辣椒素安全性评估的最终报告。
Int J Toxicol. 2007;26 Suppl 1:3-106. doi: 10.1080/10915810601163939.
4
[Allergic reaction to products made of natural rubber].对天然橡胶制品的过敏反应
Pol Tyg Lek. 1994;49(14-15):347-51.
5
Contact allergy to colophony. Clinical and experimental studies with emphasis on clinical relevance.对松香的接触性过敏。侧重于临床相关性的临床与实验研究。
Acta Derm Venereol Suppl (Stockh). 1998;201:1-42.
6
Contact allergic reactions on the eyes and eyelids.眼部及眼睑的接触性过敏反应。
Bull Soc Belge Ophtalmol. 2004(292):11-7.
7
[Contact dermatitis from hexamidine].[己脒定引起的接触性皮炎]
Ann Dermatol Venereol. 1984;111(9):805-10.
8
10 years' experience of patch testing with a shoe series in 230 patients: which allergens are important?对230名患者进行鞋类系列斑贴试验的10年经验:哪些过敏原至关重要?
Contact Dermatitis. 2005 Jul;53(1):37-9. doi: 10.1111/j.0105-1873.2005.00631.x.
9
Allergic contact dermatitis from transdermal estradiol and systemic contact dermatitis from oral estradiol. A case report.经皮雌二醇引起的变应性接触性皮炎和口服雌二醇引起的系统性接触性皮炎。病例报告。
J Reprod Med. 2002 Jun;47(6):507-9.
10
Thimerosal allergy and clinical relevance in Thailand.硫柳汞过敏及其在泰国的临床相关性。
J Med Assoc Thai. 2007 Sep;90(9):1775-9.

引用本文的文献

1
Alternating electric tumor treating fields for treatment of glioblastoma: rationale, preclinical, and clinical studies.交变电场肿瘤治疗系统治疗脑胶质瘤:原理、临床前和临床研究。
J Neurosurg. 2018 Feb;128(2):414-421. doi: 10.3171/2016.9.JNS16452. Epub 2017 Feb 24.
2
Alternating electric fields arrest cell proliferation in animal tumor models and human brain tumors.交变电场可抑制动物肿瘤模型和人类脑肿瘤中的细胞增殖。
Proc Natl Acad Sci U S A. 2007 Jun 12;104(24):10152-7. doi: 10.1073/pnas.0702916104. Epub 2007 Jun 5.
3
Allergic contact dermatitis to acrylates in disposable blue diathermy pads.
一次性蓝色透热疗法垫中丙烯酸酯引起的变应性接触性皮炎。
Ann R Coll Surg Engl. 1999 May;81(3):187-90.