Suppr超能文献

加速度计测量的日常身体活动和久坐行为——两种Actigraph型号之间的比较以及数据简化的重要性。

Accelerometer measured daily physical activity and sedentary pursuits--comparison between two models of the Actigraph and the importance of data reduction.

作者信息

Tanha Tina, Tornberg Åsa, Dencker Magnus, Wollmer Per

机构信息

Department of Clinical Sciences, Unit of Clinical Physiology and Nuclear Medicine, Skåne University Hospital, Lund University, Malmö, Sweden.

出版信息

BMC Res Notes. 2013 Oct 31;6:439. doi: 10.1186/1756-0500-6-439.

Abstract

BACKGROUND

Very few validation studies have been performed between different generations of the commonly used Actigraph accelerometers. We compared daily physical activity data generated from the old generation Actigraph model 7164 with the new generation Actigraph GT1M accelerometer in 15 young females for eight consecutive days. We also investigated if different wear time thresholds had any impact on the findings. Minutes per day of moderate and vigorous physical activity (MVPA), vigorous physical activity (VPA) and very vigorous physical activity (VVPA) were calculated. Moreover, minutes of sedentary pursuits per day were calculated.

FINDINGS

There were significant (P < 0.05) differences between the Actigraph 7164 and the GT1M concerning MVPA (61 ± 21vs. 56 ± 23 min/day), VPA (12 ± 8 vs. 9 ± 3 min/day) and VVPA (3.2 ± 3.0 vs. 0.3 ± 1.1 min/day). The different wear time thresholds had little impact on minutes per day in different intensities. Median minutes of sedentary pursuits per day ranged from 159 to 438 minutes depending on which wear time threshold was used (i.e. 10, 30 or 60 minutes), whereas very small differences were observed between the two different models.

CONCLUSIONS

Data from the old generation Actigraph 7164 and the new generation Actigraph GT1M accelerometers differ, where the Actigraph GT1M generates lower minutes spent in free living physical activity. Median minutes of sedentary pursuits per day are highly dependent on which wear time threshold that is used, and not by accelerometer model.

摘要

背景

在常用的Actigraph加速度计的不同代产品之间进行的验证研究非常少。我们连续八天比较了15名年轻女性使用旧一代Actigraph 7164型号和新一代Actigraph GT1M加速度计产生的日常身体活动数据。我们还研究了不同的佩戴时间阈值是否会对研究结果产生任何影响。计算了每天中等强度和剧烈身体活动(MVPA)、剧烈身体活动(VPA)和极剧烈身体活动(VVPA)的分钟数。此外,还计算了每天久坐不动的分钟数。

研究结果

Actigraph 7164和GT1M在MVPA(61±21对56±23分钟/天)、VPA(12±8对9±3分钟/天)和VVPA(3.2±3.0对0.3±1.1分钟/天)方面存在显著(P<0.05)差异。不同的佩戴时间阈值对不同强度下每天的分钟数影响很小。根据使用的佩戴时间阈值(即10、30或60分钟),每天久坐不动的中位数分钟数在159至438分钟之间,而在两种不同型号之间观察到的差异非常小。

结论

旧一代Actigraph 7164和新一代Actigraph GT1M加速度计的数据不同,Actigraph GT1M记录的自由生活身体活动时间较少。每天久坐不动的中位数分钟数高度依赖于使用的佩戴时间阈值,而不是加速度计型号。

相似文献

本文引用的文献

7
Validation and comparison of ActiGraph activity monitors.活动监测仪的验证与比较。
J Sci Med Sport. 2011 Sep;14(5):411-6. doi: 10.1016/j.jsams.2011.04.003. Epub 2011 May 25.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验