基于适体的生物传感器,用于灵敏检测凝血酶,使用酞菁@SiO2 介孔纳米粒子。

An aptamer-based biosensor for sensitive thrombin detection with phthalocyanine@SiO2 mesoporous nanoparticles.

机构信息

Institute of Research on Functional Materials, Cancer Metastasis Alert and Prevention Center, Fuzhou University, Fuzhou 350108, China; College of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou 350108, China.

出版信息

Biosens Bioelectron. 2014 Mar 15;53:340-5. doi: 10.1016/j.bios.2013.10.005. Epub 2013 Oct 16.

Abstract

Silica nanoparticles, with entrapped hydrophobic photosensitizer tetra-α-(2, 4-di-tert-butylphenoxy)-phthalocyaninato zinc (ZnPc(OAr)4), were synthesized by hydrolyzing triethoxyvinylsilane (TEVS) and 3-amino propyl triethoxysilane (APTES). The as-prepared nanoparticles, which were highly monodispersed spheres (about 100 nm), exhibited strong Q-band absorption of ZnPc(OAr)4 centered at 701 nm. The aqueous solubility of ZnPc(OAr)4 encapsulated in silica nanoparticles was obviously improved. The nanoparticles efficiently generated singlet oxygen ((1)O2) both in organic and aqueous solutions after being irradiated at suitable wavelength. The resulting (1)O2 then initiated chemiluminescence (CL) by reacting with a methyl cypridina luciferin analog (MCLA). Based on the photoinduced CL, a sensitive aptamer-based sandwich-type sensor was presented to detect human thrombin. Thrombin was first attached to Pc@SiO2 via secondary aptamer, and then they were collected, for CL determination, by beads with primary aptamer. The proposed approach, which was highly selective with a low detection limit of 80 pmol/L, minimized the nonspecific adsorption. Such an aptamer-based biosensor is feasible in screening biomarkers in complex matrices at ultratrace levels.

摘要

硅纳米粒子,包埋了疏水性光敏剂四-α-(2,4-二叔丁基苯氧基)酞菁锌(ZnPc(OAr)4),是通过水解三乙氧基乙烯基硅烷(TEVS)和 3-氨基丙基三乙氧基硅烷(APTES)合成的。所制备的纳米粒子高度单分散的球体(约 100nm),显示出 ZnPc(OAr)4 的强 Q 带吸收,中心位于 701nm。ZnPc(OAr)4 包封在硅纳米粒子中的水溶性明显提高。纳米粒子在合适波长的照射下,在有机和水溶液中均能有效产生单线态氧((1)O2)。生成的(1)O2 然后与甲基海葵荧光素类似物(MCLA)反应引发化学发光(CL)。基于光诱导 CL,提出了一种灵敏的基于适配体的三明治型传感器来检测人凝血酶。凝血酶首先通过二级适配体附着在 Pc@SiO2 上,然后通过带有一级适配体的珠子收集,用于 CL 测定。该方法具有较高的选择性,检测限低至 80pmol/L,最小化了非特异性吸附。这种基于适配体的生物传感器可用于在复杂基质中筛选痕量水平的生物标志物。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验