Suppr超能文献

用于检测空气中化学战剂的带有电子回旋共振离子源的便携式质谱仪的研制。

Development of portable mass spectrometer with electron cyclotron resonance ion source for detection of chemical warfare agents in air.

作者信息

Urabe Tatsuya, Takahashi Kazuya, Kitagawa Michiko, Sato Takafumi, Kondo Tomohide, Enomoto Shuichi, Kidera Masanori, Seto Yasuo

机构信息

RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan.

National Research Institute of Police Science, 6-3-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan.

出版信息

Spectrochim Acta A Mol Biomol Spectrosc. 2014;120:437-44. doi: 10.1016/j.saa.2013.10.041. Epub 2013 Oct 22.

Abstract

A portable mass spectrometer with an electron cyclotron resonance ion source (miniECRIS-MS) was developed. It was used for in situ monitoring of trace amounts of chemical warfare agents (CWAs) in atmospheric air. Instrumental construction and parameters were optimized to realize a fast response, high sensitivity, and a small body size. Three types of CWAs, i.e., phosgene, mustard gas, and hydrogen cyanide were examined to check if the mass spectrometer was able to detect characteristic elements and atomic groups. From the results, it was found that CWAs were effectively ionized in the miniECRIS-MS, and their specific signals could be discerned over the background signals of air. In phosgene, the signals of the 35Cl+ and 37Cl+ ions were clearly observed with high dose-response relationships in the parts-per-billion level, which could lead to the quantitative on-site analysis of CWAs. A parts-per-million level of mustard gas, which was far lower than its lethal dosage (LCt50), was successfully detected with a high signal-stability of the plasma ion source. It was also found that the chemical forms of CWAs ionized in the plasma, i.e., monoatomic ions, fragment ions, and molecular ions, could be detected, thereby enabling the effective identification of the target CWAs. Despite the disadvantages associated with miniaturization, the overall performance (sensitivity and response time) of the miniECRIS-MS in detecting CWAs exceeded those of sector-type ECRIS-MS, showing its potential for on-site detection in the future.

摘要

研制了一种带有电子回旋共振离子源的便携式质谱仪(miniECRIS-MS)。它用于现场监测大气中痕量化学战剂(CWA)。对仪器结构和参数进行了优化,以实现快速响应、高灵敏度和小体积。对三种类型的化学战剂,即光气、芥子气和氰化氢进行了检测,以检查该质谱仪是否能够检测特征元素和原子团。结果发现,化学战剂在miniECRIS-MS中能有效电离,其特定信号能在空气背景信号中辨别出来。在光气中,在十亿分比水平上清晰观察到35Cl+和37Cl+离子的信号,具有高剂量响应关系,这可实现化学战剂的现场定量分析。成功检测到百万分比水平的芥子气,其浓度远低于致死剂量(LCt50),且等离子体离子源具有高信号稳定性。还发现,能检测到在等离子体中电离的化学战剂的化学形式,即单原子离子、碎片离子和分子离子,从而能够有效识别目标化学战剂。尽管小型化存在缺点,但miniECRIS-MS在检测化学战剂方面的整体性能(灵敏度和响应时间)超过了扇形型ECRIS-MS,显示出其未来现场检测的潜力。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验