Department of Psychology, University of Bologna, Bologna, Italy.
Université Paris Descartes, Sorbonne Paris Cité, APHP, Hôtel-Dieu de Paris, Centre du sommeil et de la vigilance, Paris, France.
Sleep Med. 2014 Jan;15(1):111-5. doi: 10.1016/j.sleep.2013.08.792. Epub 2013 Nov 15.
The aim of our study was to evaluate quantitative actigraphic criteria obtained using the Actiwatch device (AW64; Cambridge Neurotechnology Ltd., Cambridge, UK) to differentiate participants with insomnia from normal sleepers.
In our retrospective study, we recovered 493 actigraphic records from two sleep measure databases of patients with insomnia (n=151) and one of normal sleepers (n=342). We considered the following actigraphic sleep parameters: time in bed (TIB), sleep-onset latency (SOL), total sleep time (TST), wake after sleep onset (WASO), sleep efficiency (SE), number of awakenings (NWAK), terminal wakefulness (TWAK), fragmentation index (FI), and mean motor activity (MA). We also considered two actigraphic circadian indexes: interdaily stability and intradaily variability. Using the Youden index, we calculated the quantitative actigraphic criteria that performed best for each actigraphic sleep parameter. Finally, we created receiver operating characteristic curves to test the accuracy of each criterion identified.
All sleep parameters except TST and TWAK differentiated the two groups of participants, allowing calculation of quantitative actigraphic criteria. There were no differences in the circadian indices.
The quantitative actigraphic criteria obtained in our study were not the same as those obtained previously with a different device, suggesting the need to adopt shared technical solutions for actigraphy.
我们研究的目的是评估使用 Actiwatch 设备(AW64;剑桥神经技术有限公司,英国剑桥)获得的定量活动记录仪标准,以区分失眠患者和正常睡眠者。
在我们的回顾性研究中,我们从两个失眠患者的睡眠测量数据库(n=151)和一个正常睡眠者的睡眠数据库(n=342)中恢复了 493 个活动记录仪记录。我们考虑了以下活动记录仪睡眠参数:卧床时间(TIB)、入睡潜伏期(SOL)、总睡眠时间(TST)、睡眠后觉醒时间(WASO)、睡眠效率(SE)、觉醒次数(NWAK)、终末觉醒时间(TWAK)、碎片化指数(FI)和平均运动活动(MA)。我们还考虑了两个活动记录仪昼夜节律指数:日间稳定性和日内可变性。使用 Youden 指数,我们计算了每个活动记录仪睡眠参数表现最佳的定量活动记录仪标准。最后,我们创建了接收者操作特征曲线来测试每个确定标准的准确性。
除 TST 和 TWAK 外,所有睡眠参数均能区分两组参与者,允许计算定量活动记录仪标准。昼夜节律指数没有差异。
我们研究中获得的定量活动记录仪标准与以前使用不同设备获得的标准不同,这表明需要采用共享的技术解决方案来进行活动记录仪。