Suppr超能文献

年轻人失眠时的活动记录仪的有效性。

Validity of Actigraphy in Young Adults With Insomnia.

机构信息

Department of Psychology, University of North Texas, Denton, Texas.

出版信息

Behav Sleep Med. 2020 Jan-Feb;18(1):91-106. doi: 10.1080/15402002.2018.1545653. Epub 2018 Nov 25.

Abstract

: Actigraphy is an inexpensive and objective wrist-worn activity sensor that has been validated for the measurement of sleep onset latency (SOL), number of awakenings (NWAK), wake after sleep onset (WASO), total sleep time (TST), and sleep efficiency (SE) in both middle-aged and older adults with insomnia. However, actigraphy has not been evaluated in young adults. In addition, most previous studies compared actigraphy to in-lab polysomnography (PSG), but none have compared actigraphy to more ecologically valid ambulatory polysomnography.: 21 young adults (mean age = 19.90 ± 2.19 years;  = 13 women) determined to have chronic primary insomnia through structured clinical interviews.: Sleep diaries, actigraphy, and ambulatory PSG data were obtained over a single night to obtain measures of SOL, NWAK, WASO, time spent in bed after final awakening in the morning (TWAK), TST, and SE.: Actigraphy was a valid estimate of SOL, WASO, TST, and SE, based on significant correlations ( = 0.45 to 0.87), nonsignificant mean differences between actigraphy and PSG, and inspection of actigraphy bias from Bland Altman plots (SOL α = 1.52, WASO α = 7.95, TST α = -8.60, SE α = -1.38).: Actigraphy was a valid objective measure of SOL, WASO, TST, and SE in a young adult insomnia sample, as compared to ambulatory PSG. Actigraphy may be a valid alternative for assessing sleep in young adults with insomnia when more costly PSG measures are not feasible.

摘要

动作活动记录仪是一种廉价且客观的腕部佩戴式活动传感器,已经过验证可用于测量睡眠潜伏期 (SOL)、觉醒次数 (NWAK)、睡眠起始后觉醒时间 (WASO)、总睡眠时间 (TST) 和睡眠效率 (SE),适用于患有失眠症的中年和老年成年人。然而,动作活动记录仪尚未在年轻成年人中进行评估。此外,大多数先前的研究将动作活动记录仪与实验室多导睡眠图 (PSG) 进行了比较,但没有一项研究将动作活动记录仪与更具生态有效性的可移动多导睡眠图进行了比较。

我们纳入了 21 名年轻成年人(平均年龄 19.90 ± 2.19 岁;女性 13 名),通过结构化临床访谈确定他们患有慢性原发性失眠症。

在一个晚上内同时获得睡眠日记、动作活动记录仪和可移动 PSG 数据,以获得 SOL、NWAK、WASO、早晨最后一次醒来后在床上的时间 (TWAK)、TST 和 SE 的测量值。

动作活动记录仪是 SOL、WASO、TST 和 SE 的有效估计值,这基于显著的相关性 (r = 0.45 至 0.87)、动作活动记录仪和 PSG 之间无显著的均值差异,以及 Bland-Altman 图中的动作活动记录仪偏差检查 (SOL α = 1.52,WASO α = 7.95,TST α = -8.60,SE α = -1.38)。

与可移动 PSG 相比,在年轻成年人失眠样本中,动作活动记录仪是 SOL、WASO、TST 和 SE 的有效客观测量值。当更昂贵的 PSG 测量值不可行时,动作活动记录仪可能是评估患有失眠症的年轻成年人睡眠的有效替代方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验