Suppr超能文献

储存的单供体血小板浓缩物中血栓弹力图反应性的测定。

Determination of thromboelastographic responsiveness in stored single-donor platelet concentrates.

机构信息

Sanquin Blood Supply, Amsterdam, the Netherlands.

出版信息

Transfusion. 2014 Jun;54(6):1610-8. doi: 10.1111/trf.12515. Epub 2013 Dec 16.

Abstract

BACKGROUND

Thromboelastography (TEG) is widely used in hospitals but less commonly in blood banks for evaluation of platelet (PLT) concentrates (PCs). A TEG-PC assay for testing fresh or stored PLTs must reflect the quality of the PLTs. The added value could be measurement of donor-dependent PLT quality.

STUDY DESIGN AND METHODS

Whole blood (WB) normal values were generated from 100 donors, using standard tests. Nineteen single-donor PCs were evaluated with a TEG-PC assay, using Octaplas as microparticle-free diluent and kaolin or collagen as activator, stored up to 12 days, and also sampled for additional in vitro tests.

RESULTS

WB values showed larger reaction rates (R- and K-times, angle) compared to the reference values and almost similar maximum amplitude (MA). PCs showed usual storage lesion and TEG-PC results showed significant decreasing R- and K-times and increasing angle. Mean MA values remained constant but individual measurements were affected by clot retraction. TEG tracings of two PCs with good quality on Day 12 showed weak to strong clot retraction, while two PCs with poor quality showed moderate clot retraction on Day 1, no clot retraction on Days 5 to 12, and a decreased MA on Day 12. Clot strength (MA) and especially clot retraction represent possibly donor-specific effects.

CONCLUSION

A TEG-PC assay has been developed that is sensitive to storage effects. The assay has the potential to be helpful in selection of PLT donors but needs improvement to be more sensitive, reproducible, and distinctive to determine whose PLTs store poorly and whose store well.

摘要

背景

血栓弹力描记术(TEG)在医院中广泛应用,但在血库中用于评估血小板(PLT)浓缩物(PC)的情况较少。用于检测新鲜或储存 PLT 的 TEG-PC 检测必须反映 PLT 的质量。其附加值可能是测量供体依赖性 PLT 质量。

研究设计和方法

使用标准检测,从 100 名供体中生成全血(WB)正常值。使用 Octaplas 作为无微粒稀释剂和高岭土或胶原作为激活剂,对 19 个单供体 PC 进行 TEG-PC 检测,储存时间长达 12 天,并进行额外的体外检测。

结果

WB 值的反应速率(R-和 K-时间、角度)与参考值相比更大,最大振幅(MA)几乎相同。PC 显示出常见的储存损伤,TEG-PC 结果显示 R-和 K-时间显著缩短,角度增加。平均 MA 值保持不变,但个别测量值受凝块回缩的影响。在第 12 天,2 个质量良好的 PC 的 TEG 轨迹显示出弱至强的凝块回缩,而 2 个质量差的 PC 在第 1 天显示出中度凝块回缩,第 5 至 12 天无凝块回缩,第 12 天 MA 降低。凝块强度(MA),特别是凝块回缩,可能代表供体特异性影响。

结论

已经开发出一种对储存效果敏感的 TEG-PC 检测方法。该检测方法有可能有助于选择 PLT 供体,但需要改进以提高其敏感性、重现性和独特性,以确定哪些 PLT 储存效果差,哪些储存效果好。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验