Suppr超能文献

评估悬浮于低血浆水平的含碳酸氢盐添加剂溶液中且在储存时有24小时搅拌中断的单采血小板的体外储存特性。

Evaluation of in vitro storage properties of apheresis platelets suspended in a bicarbonate-containing additive solution with low levels of plasma and stored with a 24-hour interruption of agitation.

作者信息

Skripchenko A, Turgeon A, Thompson-Montgomery D, Awatefe H, Wagner S J

机构信息

American Red Cross Biomedical Services, Holland Laboratory, Rockville, MD, USA.

出版信息

Vox Sang. 2014 May;106(4):337-43. doi: 10.1111/vox.12113. Epub 2013 Dec 12.

Abstract

BACKGROUND AND OBJECTIVES

PLT additive solutions (PAS) are useful for reducing the frequency and/or severity of plasma-associated transfusion reactions. A new PAS solution, PAS-5, containing 5% plasma, maintains in vitro PLT properties during 7-day storage. Periods with interruption of agitation (IA) ≤24 h routinely occur during PLT shipment and do not usually compromise platelet quality. The aim of the study was to evaluate the properties of PLTs stored for 7 days in 95% PAS-5/5% plasma subjected to a 24-h IA.

MATERIALS AND METHODS

Double apheresis Amicus units (n = 12) were collected using a manual PAS-5 addition to hyperconcentrated PLTs. PLT units were equally divided in two containers. Control and test PLTs were stored with continuous agitation at 20-24°C except for 24-h IA period for test units between days 2-3.

RESULTS

During storage, levels of glucose, lactate, mitochondrial membrane potential and aggregation significantly differed in test units compared to those of control. The pH levels of test PLTs were less than those of control units with 7/12 test units having pHs <6·2 on Day 7 compared to 1/12 control units. Morphology score, GP1bα expression, ESC values, superoxide production were also less, and activation was greater in test PLTs than those of control. All other parameters were similar between test and control units.

CONCLUSION

PLTs stored in PAS-5 solution containing 5% plasma with a 24-h IA results in marked decrements in many in vitro PLT quality parameters during 7-day storage.

摘要

背景与目的

血小板添加剂溶液(PAS)有助于降低与血浆相关的输血反应的频率和/或严重程度。一种新的PAS溶液PAS-5含有5%的血浆,在7天储存期间能维持血小板的体外特性。血小板运输过程中常规会出现搅拌中断(IA)≤24小时的情况,通常不会影响血小板质量。本研究的目的是评估在95% PAS-5/5%血浆中储存7天并经历24小时IA的血小板的特性。

材料与方法

使用手动添加PAS-5至超浓缩血小板的方法收集双份单采阿美库单位(n = 12)。血小板单位平均分为两个容器。对照和测试血小板在20 - 24°C下持续搅拌储存,测试单位在第2 - 3天之间有24小时的IA期。

结果

储存期间,测试单位的葡萄糖、乳酸、线粒体膜电位和聚集水平与对照相比有显著差异。测试血小板的pH值低于对照单位,7/12的测试单位在第7天pH值<6.2,而对照单位为1/12。测试血小板的形态学评分、糖蛋白1bα表达、ESC值、超氧化物生成也较低,且激活程度高于对照。测试和对照单位的所有其他参数相似。

结论

在含有5%血浆的PAS-5溶液中储存并经历24小时IA的血小板,在7天储存期间许多体外血小板质量参数会显著下降。