18F-FDG-PET 和 PET/CT 对良恶性胸膜病变鉴别诊断的诊断准确性:系统评价和荟萃分析。

Diagnostic accuracy of 18F-FDG-PET and PET/CT in the differential diagnosis between malignant and benign pleural lesions: a systematic review and meta-analysis.

机构信息

Department of Nuclear Medicine and PET/CT Center, Oncology Institute of Southern Switzerland, via Ospedale, 12; 6500; Bellinzona, Switzerland.

Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

出版信息

Acad Radiol. 2014 Jan;21(1):11-20. doi: 10.1016/j.acra.2013.09.015.

Abstract

RATIONALE AND OBJECTIVES

To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions.

METHODS AND MATERIALS

A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed.

RESULTS

Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found.

CONCLUSIONS

(18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind.

摘要

背景和目的

系统回顾和荟萃分析已发表的关于氟-18-氟代脱氧葡萄糖(18F-FDG)正电子发射断层扫描(PET)和 PET/计算机断层扫描(CT)在鉴别良恶性胸膜病变中的诊断准确性的资料。

方法和材料

对截至 2013 年 6 月发表的关于 18F-FDG-PET 和 PET/CT 在胸膜病变鉴别诊断中的诊断性能的研究进行了全面的文献检索。对所有检索到的研究进行了回顾和定性分析。基于患者的分析,计算了 18F-FDG-PET 或 PET/CT 在胸膜病变鉴别诊断中的汇总敏感性、特异性、阳性和阴性似然比(LR+和 LR-)和诊断比值比(DOR)。计算汇总受试者工作特征曲线下面积(AUC)以评估这些方法的准确性。进行了考虑使用设备(PET 或 PET/CT)的亚分析。

结果

共纳入了 16 项研究,包括 745 例患者。对 11 项选定研究的荟萃分析提供了以下结果:敏感性 95%(95%置信区间[95%CI]:92-97%),特异性 82%(95%CI:76-88%),LR+ 5.3(95%CI:2.4-11.8),LR- 0.09(95%CI:0.05-0.14),DOR 74(95%CI:34-161)。AUC 为 0.95。仅考虑 PET/CT 研究并未发现诊断准确性有显著提高。

结论

18F-FDG-PET 和 PET/CT 是鉴别良恶性胸膜病变的准确诊断成像方法;然而,应牢记可能导致假阴性和假阳性结果的原因。