Suppr超能文献

在7T场强下使用双调谐直肠内线圈,将磷磁共振波谱成像与氢磁共振波谱成像相结合用于人体前列腺成像。

(31) P MR spectroscopic imaging combined with (1) H MR spectroscopic imaging in the human prostate using a double tuned endorectal coil at 7T.

作者信息

Luttje Mariska P, Italiaander Michel G M, Arteaga de Castro Catalina S, van der Kemp Wybe J M, Luijten Peter R, van Vulpen Marco, van der Heide Uulke A, Klomp Dennis W J

机构信息

Imaging Division, University Medical Center, Utrecht, Netherlands.

出版信息

Magn Reson Med. 2014 Dec;72(6):1516-21. doi: 10.1002/mrm.25070. Epub 2013 Dec 19.

Abstract

PURPOSE

Improved diagnostic sensitivity could be obtained in cancer detection and staging when individual compounds of the choline pool can be detected. Therefore, a novel coil design is proposed, providing the ability to acquire both (1) H and (31) P magnetic resonance spectroscopic imaging (MRSI) in patients with prostate cancer.

METHODS

A two-element (1) H/(31) P endorectal coil was designed by adjusting a commercially available 3T endorectal coil. The two-element coil setup was interfaced as a transceiver to a whole body 7T MR scanner. Simulations and phantom measurements were performed to compare the efficiency of the coil. (1) H MRSI and (31) P MRSI were acquired in vivo in prostate cancer patients.

RESULTS

The efficiency of the (1) H/(31) P coil is comparable to the dual channel (1) H coil previously published. Individually distinguishable phospholipid metabolites in the in vivo (31) P spectra were: phosphoethanolamine, phosphocholine, phosphate, glycerophosphoethanolamine, glycerophosphocholine, phosphocreatine, and adenosine triposphate. (1) H MRSI was performed within the same scan session, visualizing choline, polyamines, creatine, and citrate.

CONCLUSION

(1) H MRSI and (31) P MRSI can be acquired in the human prostate at 7T within the same scan session using an endorectal coil matched and tuned for (1) H (quadrature) and (31) P (linear) without the need of cable traps and with negligible efficiency losses in the (1) H and (31) P channel.

摘要

目的

当能够检测胆碱池中的单个化合物时,在癌症检测和分期中可获得更高的诊断灵敏度。因此,提出了一种新型线圈设计,能够在前列腺癌患者中同时获取(1)H和(31)P磁共振波谱成像(MRSI)。

方法

通过调整市售的3T直肠内线圈设计了一种双元(1)H/(31)P直肠内线圈。将双元线圈装置作为收发器连接到全身7T MR扫描仪。进行了模拟和模型测量以比较线圈的效率。在前列腺癌患者体内获取了(1)H MRSI和(31)P MRSI。

结果

(1)H/(31)P线圈的效率与先前发表的双通道(1)H线圈相当。体内(31)P波谱中可单独区分的磷脂代谢物有:磷酸乙醇胺、磷酸胆碱、磷酸盐、甘油磷酸乙醇胺、甘油磷酸胆碱、磷酸肌酸和三磷酸腺苷。在同一次扫描过程中进行了(1)H MRSI,显示了胆碱、多胺、肌酸和柠檬酸盐。

结论

使用针对(1)H(正交)和(31)P(线性)匹配和调谐的直肠内线圈,无需电缆陷波器,且(1)H和(31)P通道的效率损失可忽略不计,在7T条件下可在同一次扫描过程中在人体前列腺中获取(1)H MRSI和(31)P MRSI。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验