Kim Jin-Kyoung, Kim Duk-Kyung, Lee Myeong-Jin
Department of Anaesthesia and Pain Medicine, Samsung Medical Centre, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
J Int Med Res. 2014 Feb;42(1):130-7. doi: 10.1177/0300060513505525. Epub 2013 Dec 23.
To determine bispectral index (BIS) values produced by equipotent concentrations of commonly used volatile anaesthetics.
Female patients undergoing thyroidectomy were randomly assigned to receive isoflurane, sevoflurane or desflurane anaesthesia. After induction, anaesthesia was maintained by the volatile agent at 1 minimum alveolar concentration and supplemented with remifentanil infusion. BIS values were recorded during 1 h surgical anaesthesia after a 15 min equilibrium phase.
Time-averaged BIS value during the study period was significantly lower in the desflurane group (n = 29) than the sevoflurane group (n = 27) (37.0 ± 4.9 vs 41.5 ± 5.9). Duration of deep hypnosis (BIS < 40) was significantly longer in the desflurane group than the sevoflurane group (40.2 ± 20.7 vs 24.3 ± 22.5 min). There were no significant differences in any parameter between the isoflurane group (n = 27) and any other group.
Desflurane produces a greater hypnotic effect than sevoflurane during equipotent anaesthesia. Management of volatile anaesthesia using predetermined minimum alveolar concentration targets can lead to an unnecessarily long duration of deep hypnosis.
确定常用挥发性麻醉剂等效浓度产生的脑电双频指数(BIS)值。
将接受甲状腺切除术的女性患者随机分配接受异氟烷、七氟烷或地氟烷麻醉。诱导后,用挥发性麻醉剂维持麻醉在1个最低肺泡浓度,并补充瑞芬太尼输注。在15分钟平衡期后的1小时手术麻醉期间记录BIS值。
地氟烷组(n = 29)研究期间的时间平均BIS值显著低于七氟烷组(n = 27)(37.0±4.9对41.5±5.9)。地氟烷组深度催眠(BIS<40)的持续时间显著长于七氟烷组(40.2±20.7对24.3±22.5分钟)。异氟烷组(n = 27)与其他任何组之间在任何参数上均无显著差异。
在等效麻醉期间,地氟烷比七氟烷产生更大的催眠作用。使用预定的最低肺泡浓度目标进行挥发性麻醉管理可能导致不必要的长时间深度催眠。