Kawa-Iwanicka Aneta, Lobodziec Włodzimierz, Dybek Marcin, Nenko Dorota, Iwanicki Tomasz
Radiotherapy Department, Stanislaw Leszczynski Memorial Hospital, Katowice, Poland.
Rep Pract Oncol Radiother. 2012 Aug 21;17(6):367-75. doi: 10.1016/j.rpor.2012.07.013. eCollection 2012.
To analyze and compare dose distribution homogeneity in selected points (especially in the chest wall region) for patients irradiated with two different TBI techniques to achieve a uniform total dose (excluding lungs area) specified in the range of 11.4-14.0 Gy.
From August 2000 to December 2009, a group of 158 patients was treated by the use of 15 MV photon irradiation consisting of six fractions: four opposed lateral and two anterior-posterior/posterior-anterior (AP/PA). Patients were irradiated with the fraction dose of 2 Gy twice a day for 3 consecutive days. The prescribed dose to PC point (specified at intersection of the beam axis with the mid-plane of the patient irradiated laterally) was 12 Gy. Since January 2010 until closing the study, another group of 50 patients was treated according to a modified protocol. The treatment was carried out in six lateral fractions only, twice a day, for three following days and a lateral lung shield was used for a part of total irradiation time. The measurements of doses in 20 selected points of patient's body were carried out by means of MOSFET detectors.
The modified TBI technique allows to achieve an expected homogenous dose in the points of interest similar to that obtained by using the initial protocol. The calculated and measured in vivo doses met the specified range of 11.4-14 Gy for both applied TBI protocols.
Our results indicate that for all patients the homogenous dose distribution in the specified range was achieved.
分析并比较采用两种不同全身照射(TBI)技术对患者进行照射时,特定点(尤其是胸壁区域)的剂量分布均匀性,以实现11.4 - 14.0 Gy范围内规定的均匀总剂量(不包括肺部区域)。
2000年8月至2009年12月,一组158例患者接受了15 MV光子照射,共六次分割:四次对侧野和两次前后/后前(AP/PA)野。患者每天两次,每次分割剂量为2 Gy,连续照射3天。规定的PC点(定义为射束轴与侧向照射患者的中平面的交点)剂量为12 Gy。自2010年1月至研究结束,另一组50例患者按照改良方案进行治疗。治疗仅采用六个侧野分割,每天两次,连续三天,并在部分总照射时间使用侧肺挡铅。通过MOSFET探测器对患者身体20个选定部位的剂量进行测量。
改良的TBI技术能够在感兴趣点实现与初始方案相似的预期均匀剂量。两种应用的TBI方案的计算和体内测量剂量均符合11.4 - 14 Gy的规定范围。
我们的结果表明,所有患者均在规定范围内实现了均匀的剂量分布。