Comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film with a commercial radiation treatment planning system for breast IMRT: a feasibility study.

机构信息

The University of Texas M D Anderson Cancer, The Islamia University, Shaukat Khanum Cancer Hospital & Research Center.

出版信息

J Appl Clin Med Phys. 2014 Jan 6;15(1):4531. doi: 10.1120/jacmp.v15i1.4531.

Abstract

This work presents a comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film measurements with a commercial treatment planning system to determine the feasibility of PRESAGE® for 3D dosimetry in breast IMRT. An anthropomorphic PRESAGE® phantom was created in the shape of a breast phantom. A five-field IMRT plan was generated with a commercially available treatment planning system and delivered to the PRESAGE® phantom. The anthropomorphic PRESAGE® was scanned with the Duke midsized optical CT scanner (DMOS-RPC) and the OD distribution was converted to dose. Comparisons were performed between the dose distribution calculated with the Pinnacle3 treatment planning system, PRESAGE®, and EBT2 film measurements. DVHs, gamma maps, and line profiles were used to evaluate the agreement. Gamma map comparisons showed that Pinnacle3 agreed with PRESAGE® as greater than 95% of comparison points for the PTV passed a ± 3%/± 3 mm criterion when the outer 8 mm of phantom data were discluded. Edge artifacts were observed in the optical CT reconstruction, from the surface to approximately 8 mm depth. These artifacts resulted in dose differences between Pinnacle3 and PRESAGE® of up to 5% between the surface and a depth of 8 mm and decreased with increasing depth in the phantom. Line profile comparisons between all three independent measurements yielded a maximum difference of 2% within the central 80% of the field width. For the breast IMRT plan studied, the Pinnacle3 calculations agreed with PRESAGE® measurements to within the ±3%/± 3 mm gamma criterion. This work demonstrates the feasibility of the PRESAGE® to be fashioned into anthropomorphic shape, and establishes the accuracy of Pinnacle3 for breast IMRT. Furthermore, these data have established the groundwork for future investigations into 3D dosimetry with more complex anthropomorphic phantoms.

摘要

这项工作比较了仿人型 PRESAGE®剂量计和光致变色胶片测量与商业治疗计划系统,以确定 PRESAGE®在乳腺癌调强放射治疗(IMRT)中的 3D 剂量测定的可行性。创建了一个仿人型 PRESAGE®体模,形状为乳房体模。使用商业上可用的治疗计划系统生成了五个场的 IMRT 计划,并将其输送到 PRESAGE®体模。使用 Duke 中型光学 CT 扫描仪(DMOS-RPC)对仿人型 PRESAGE®进行扫描,并将 OD 分布转换为剂量。在使用 Pinnacle3 治疗计划系统、PRESAGE®和 EBT2 胶片测量的剂量分布之间进行了比较。使用剂量体积直方图(DVH)、伽马图和线轮廓来评估一致性。伽马图比较表明,当排除体模数据的外 8mm 时,Pinnacle3 与 PRESAGE®的一致性大于 95%,因为 PTV 的大于 95%的比较点通过了±3%/±3mm 的标准。在光学 CT 重建中观察到边缘伪影,从表面到大约 8mm 深度。这些伪影导致 Pinnacle3 和 PRESAGE®之间的剂量差异,在表面和 8mm 深度之间最大可达 5%,并随着体模深度的增加而减小。所有三种独立测量之间的线轮廓比较在 80%的场宽中心内最大差异为 2%。对于所研究的乳腺癌 IMRT 计划,Pinnacle3 计算结果与 PRESAGE®测量结果在±3%/±3mm 伽马标准内一致。这项工作证明了将 PRESAGE®塑造成仿人形状的可行性,并确定了 Pinnacle3 用于乳腺癌 IMRT 的准确性。此外,这些数据为未来使用更复杂的仿人型体模进行 3D 剂量测定的研究奠定了基础。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4fe5/5711233/f2f311cac9ac/ACM2-15-363-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索