Suppr超能文献

多发性骨髓瘤患者诊断时旋转血栓弹力图(ROTEM)参数的评估。

Assessment of rotation thromboelastometry (ROTEM) parameters in patients with multiple myeloma at diagnosis.

作者信息

Treliński Jacek, Misiewicz Małgorzata, Robak Marta, Smolewski Piotr, Chojnowski Krzysztof

机构信息

Department of Haematology, Copernicus Memorial Hospital, Medical University of Łódź, Poland.

Department of Haematology, Copernicus Memorial Hospital, Medical University of Łódź, Poland.

出版信息

Thromb Res. 2014 Apr;133(4):667-70. doi: 10.1016/j.thromres.2014.01.011. Epub 2014 Jan 14.

Abstract

INTRODUCTION

Patients with multiple myeloma (MM) have an increased risk of thromboembolic events (TEE). Due to the complex nature of the prothrombotic state in MM, no single laboratory test has been designed to identify patients with the highest risk of developing TEE. Hence, this study is intended to assess the feasibility of using global hemostasis test rotation thromboelastometry (ROTEM) in MM patients to identify the presence of changes indicating hypercoagulability.

MATERIALS AND METHODS

The study included 26 patients with MM at the time of diagnosis and 20 healthy volunteers. Clotting time (CT), clot formation time (CFT), alpha angle (α), maximum clot firmness (MCF) and maximum lysis (ML) were among the most important parameters recorded during the NATEM, INTEM, EXTEM, FIBTEM and APTEM tests.

RESULTS

For the NATEM test, CT and CFT readings were markedly lower in MM patients than in controls (524s v. 753s; p=0.0006 and 136s v. 242s; p=0.02 respectively). However, no marked differences concerning these parameters were observed in the INTEM, EXTEM, FIBTEN or APTEM tests. α-angle values were significantly higher for MM samples according to the NATEM, EXTEM, FIBTEM and APTEM tests (64° v. 48.5°, p=0.02; 77° v. 74°, p=0.02; 80° v.69.5°, p=0.00007; 77° v. 74°, p=0.01 respectively). MCF readings were significantly higher in the FIBTEM test (22mm v. 15.5mm, p=0.0003) in MM patients. Also, the NATEM test revealed a trend toward higher MCF values in MM samples (56mm v. 49.5mm, p=0.055). No marked differences were seen in the INTEM, EXTEM and APTEM tests. ML readings were markedly lower (0 % v. 4.5 %, p=0.0008) in MM samples than in controls according to the FIBTEM test. The studied clot lysis parameters did not differ markedly between analyzed groups in other tests. Marked negative correlations were noted between IgG concentration and CT (EXTEM, FIBTEM) and CFT (INTEM), as well as a significant positive correlation between IgG concentration and MCF (INTEM, FIBTEM) and α (INTEM) in MM IgG patients.

CONCLUSIONS

Our results suggest that patients with MM display changes in ROTEM tests at the time of diagnosis that may indicate a prothrombotic state.

摘要

引言

多发性骨髓瘤(MM)患者发生血栓栓塞事件(TEE)的风险增加。由于MM患者血栓前状态的复杂性,尚未设计出单一的实验室检测方法来识别发生TEE风险最高的患者。因此,本研究旨在评估使用全球止血检测旋转血栓弹力图(ROTEM)对MM患者进行检测以识别表明高凝状态变化的可行性。

材料与方法

本研究纳入了26例确诊时的MM患者和20名健康志愿者。凝血时间(CT)、凝血形成时间(CFT)、α角、最大血凝块硬度(MCF)和最大溶解率(ML)是在NATEM、INTEM、EXTEM、FIBTEM和APTEM检测过程中记录的最重要参数。

结果

对于NATEM检测,MM患者的CT和CFT读数显著低于对照组(分别为524秒对753秒;p = 0.0006和136秒对242秒;p = 0.02)。然而,在INTEM、EXTEM、FIBTEN或APTEM检测中,未观察到这些参数的显著差异。根据NATEM、EXTEM、FIBTEM和APTEM检测,MM样本的α角值显著更高(分别为64°对48.5°,p = 0.02;77°对74°,p = 0.02;80°对69.5°,p = 0.00007;77°对74°,p = 0.01)。在FIBTEM检测中,MM患者的MCF读数显著更高(22毫米对15.5毫米,p = 0.0003)。此外,NATEM检测显示MM样本中MCF值有升高趋势(56毫米对49.5毫米,p = 0.055)。在INTEM、EXTEM和APTEM检测中未观察到显著差异。根据FIBTEM检测,MM样本的ML读数显著低于对照组(0%对4.5%,p = 0.0008)。在其他检测中,各分析组之间研究的血凝块溶解参数无显著差异。在MM IgG患者中,IgG浓度与CT(EXTEM、FIBTEM)和CFT(INTEM)之间存在显著负相关,与MCF(INTEM、FIBTEM)和α(INTEM)之间存在显著正相关。

结论

我们的结果表明,MM患者在诊断时ROTEM检测出现变化,可能表明处于血栓前状态。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验