Suppr超能文献

Descemet 撕囊自动化内皮角膜移植术中纹理界面混浊的临床病理相关性:病例研究。

Clinicopathologic correlation of textural interface opacities in descemet stripping automated endothelial keratoplasty: a case study.

机构信息

*Central Pennsylvania Eye Institute, Hershey, PA; and †Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL.

出版信息

Cornea. 2014 Mar;33(3):306-9. doi: 10.1097/ICO.0000000000000057.

Abstract

PURPOSE

The aim of this study was to describe the clinicopathologic correlation of textural interface opacities (TIOs) in a Descemet stripping automated endothelial keratoplasty (DSAEK) donor button after its removal.

METHODS

A 75-year-old woman underwent combined phacoemulsification with intraocular lens placement and DSAEK in her right eye. She had TIOs 1 week postoperatively and continued to have poor visual acuity 8 months postoperatively. The original DSAEK graft was removed, and a repeat DSAEK procedure with a new donor disc was performed. A control corneal button was obtained from a 79-year-old woman who suffered chronic rejection and had a failed DSAEK. Both corneal specimens were sent for light and electron microscopy.

RESULTS

Light microscopy of the donor tissue from the patient with TIOs showed stromal irregularities projecting from the cut anterior surface and the expected decrease in the endothelial cell density associated with the procedure and with artifacts. Electron microscopy examination showed irregular collagen fibrils of varying lengths at the stromal surface. Light and electron microscopy examination of the donor tissue from the control patient showed a smooth anterior stromal surface without projecting collagen fibrils.

CONCLUSIONS

The histopathology of the endothelial disc from the patient with TIOs demonstrated variably irregular lamellae that extended from the anterior donor corneal stromal surface. These extending lamellae were absent on the anterior stromal surface of the control corneal disc, suggesting that they are one possible cause of TIOs and the subsequent suboptimal best-corrected visual acuity and quality of vision experienced by a subset of DSAEK-operated patients.

摘要

目的

本研究旨在描述在去除后的 Descemet 撕囊自动内皮角膜移植(DSAEK)供体角膜瓣中,纹理界面混浊(TIOs)的临床病理相关性。

方法

一名 75 岁女性右眼接受了白内障超声乳化联合人工晶状体植入和 DSAEK。她在术后 1 周出现 TIOs,并在术后 8 个月持续视力不佳。移除原始 DSAEK 移植物,并进行重复的 DSAEK 手术,使用新的供体盘。从一名 79 岁患有慢性排斥反应和 DSAEK 失败的女性中获得对照角膜瓣。两个角膜标本均用于光镜和电镜检查。

结果

TIO 患者供体组织的光镜检查显示从前表面切出的基质不规则突出,并伴有与手术相关的和人工制品的预期内皮细胞密度降低。电子显微镜检查显示基质表面的胶原纤维不规则,长度不一。对照患者供体组织的光镜和电镜检查显示前基质表面光滑,无突出的胶原纤维。

结论

TIO 患者的内皮盘组织病理学显示从前供体角膜基质表面延伸的变异性不规则板层。这些延伸的板层在对照角膜盘的前基质表面缺失,表明它们是 TIOs 及其随后部分 DSAEK 手术患者的最佳矫正视力和视觉质量下降的一个可能原因。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验