Suppr超能文献

图形视网膜电图(pattern ERG)和图形视觉诱发电位(pattern VEP)参数的眼间振幅和潜伏期差异。

Interocular amplitude and latency differences of pattern ERG and pattern VEP parameters.

作者信息

Fejes Imre, Kocsis Péter Balázs, Benedek György, Janáky Márta

机构信息

*MD, PhD †MD ‡MD, DSc Department of Ophthalmology, Albert Szent-Györgyi Clinical Center, Faculty of Medicine, University of Szeged, Szeged, Hungary (IF, PBK, MJ); and Department of Physiology, Faculty of Medicine, University of Szeged, Szeged, Hungary (GB).

出版信息

Optom Vis Sci. 2014 Apr;91(4):472-6. doi: 10.1097/OPX.0000000000000193.

Abstract

PURPOSE

To determine the normal interocular differences in amplitudes and peak times of the pattern electroretinograms (PERGs) and pattern visual evoked potentials (PVEPs) and to investigate whether the PERG and PVEP parameters correspond in lateral dominance or whether the eye-side distributions of the functional parameters are similar.

METHODS

The PERGs and PVEPs were recorded in healthy subjects (N = 77) according to the standards of the International Society for Clinical Electrophysiology of Vision, with the modification of the check size of the PERG to 0.5 degrees. This allows stimulation of the macular ganglion cells and their corresponding visual pathways in healthy subjects.

RESULTS

Comparison of the averaged higher and lower response amplitudes and the shorter and longer response peak times showed significant differences (p < 0.001) in both the PERG and the PVEP parameters (median [5 to 95%]): the P50 (1.92% [0 to 5.48%]) and N95 (2.06% [0 to 13.95%]) peak times and the P50 (11.82% [1.32 to 29.93%) and N95 (9.45% [1.17 to 30.38%]) amplitudes of the PERGs and the P100 (1.04% [0 to 4.15%]) and N135 (1.96% [0 to 12.36%]) peak times and the P100 (9.86% [1.26 to 29.76%]) and N135 (11.19% [1.18 to 29.99%]) amplitudes of the PVEPs. No significant correlation was found concerning the eye dominance of the PERG and PVEP parameters.

CONCLUSIONS

Our results reveal a significant interocular difference on PERG and PVEP recording, but this could not be ascribed to the anatomy of the retina and related visual pathways. If the difference between the eyes is not taken into account, misinterpretation may occur in a pathological process.

摘要

目的

确定图形视网膜电图(PERG)和图形视觉诱发电位(PVEP)的振幅和峰时的正常眼间差异,并研究PERG和PVEP参数在优势眼方面是否对应,或者功能参数的眼侧分布是否相似。

方法

根据国际视觉临床电生理学会的标准,对77名健康受试者记录PERG和PVEP,并将PERG的检查大小修改为0.5度。这能够刺激健康受试者的黄斑神经节细胞及其相应的视觉通路。

结果

比较平均较高和较低的反应振幅以及较短和较长的反应峰时,发现PERG和PVEP参数(中位数[5%至95%])均存在显著差异(p < 0.001):PERG的P50(1.92%[0至5.48%])和N95(2.06%[0至13.95%])峰时以及P50(11.82%[1.32至29.93%])和N95(9.45%[1.17至30.38%])振幅,PVEP的P100(1.04%[0至4.15%])和N135(1.96%[0至12.36%])峰时以及P100(9.86%[1.26至29.76%])和N135(11.19%[1.18至29.99%])振幅。未发现PERG和PVEP参数的优势眼之间存在显著相关性。

结论

我们的结果揭示了PERG和PVEP记录存在显著的眼间差异,但这不能归因于视网膜和相关视觉通路的解剖结构。如果不考虑两眼之间的差异,在病理过程中可能会出现错误解读。