J Chromatogr A. 2014 Mar 14;1333:99-105. doi: 10.1016/j.chroma.2014.01.062. Epub 2014 Jan 27.

Abstract

In this work, an ion mobility spectrometer (IMS) with a tritium ionization source on-line coupled to a headspace (HS) autosampler and a multicapillary column (MCC) was evaluated for the monitoring of lipid oxidation products in milk with different flavours (cacao, fruits, cereals and nuts) and linseed oil samples enriched with omega-3 acids. In this combination, the multicapillary column is used as an interface between the HS and the IMS, providing the efficient separation of the volatile compounds. In this way, the proposed method permits the detection of hexanal, 2-butanone, acetone and dimethyl sulfide as representative degradation products. The limits of detection were in the interval 0.3 μg L(-1) (for hexanal in milk) to 3.0 μg L(-1) (for dimethyl sulfide in linseed oil) while the limits of quantification varied between 1.1 μg L(-1) (for hexanal in milk) and 9.6 μg L(-1) (for dimethyl sulfide in linseed oil). The precision of the method was evaluated as relative standard deviation and the values were better than 8% in all cases. The evolution of the volatiles profile during 36 days under different storage conditions (temperature, oxygen and light) demonstrates the capability of the HS-MCC-IMS coupling for the estimation of the degradation of the samples. After the degradation study, it can be concluded that the stability of the milk samples during storage is more affected by the light while temperature was more critical for oil samples.

摘要

在这项工作中,评估了一种在线耦合带有氚离子源的离子迁移谱仪(IMS)与顶空(HS)自动进样器和多毛细管柱(MCC),用于监测具有不同风味(可可、水果、谷物和坚果)的牛奶和富含 omega-3 酸的亚麻籽油样品中的脂质氧化产物。在这种组合中,多毛细管柱用作 HS 和 IMS 之间的接口,提供挥发性化合物的有效分离。通过这种方式,所提出的方法允许检测到作为代表性降解产物的己醛、2-丁酮、丙酮和二甲基硫。检测限在 0.3μg/L(牛奶中的己醛)到 3.0μg/L(亚麻籽油中的二甲基硫)之间,而定量限在 1.1μg/L(牛奶中的己醛)到 9.6μg/L(亚麻籽油中的二甲基硫)之间。该方法的精密度作为相对标准偏差进行评估,在所有情况下,其值均优于 8%。在不同储存条件(温度、氧气和光照)下 36 天期间挥发性图谱的演变证明了 HS-MCC-IMS 耦合用于估计样品降解的能力。降解研究后,可以得出结论,储存过程中牛奶样品的稳定性受光照影响更大,而温度对油样的影响更为关键。