Suppr超能文献

干燥综合征的唾液腺闪烁扫描术。视觉分析与半定量分析诊断效能的比较。

Salivary gland scintigraphy in Sjögren's syndrome. Comparison of the diagnostic performance of visual and semiquantitative analysis.

作者信息

Kim H-A, Yoon S-H, Yoon J-K, Lee S J, Jo K S, Lee D H, Suh C-H, An Y-S

机构信息

Young-Sil An, M.D., Ph.D., Department of Nuclear Medicine and Molecular Imaging, School of Medicine, Ajou University, Woncheon-dong, Yeongtong-gu, Gyeonggi-do, Suwon, Korea 443-749, Tel. +82/31/219-5948, Fax +82/31/219-5950, E-mail:

出版信息

Nuklearmedizin. 2014 Aug 6;53(4):139-45. doi: 10.3413/Nukmed-0630-13-10. Epub 2014 Feb 26.

Abstract

UNLABELLED

The aim of this study was to compare the diagnostic utility of visual versus semi-quantitative analysis of salivary gland scintigraphy in the diagnosis of Sjögren's syndrome (SS).

PATIENTS, METHODS: 99mTc-pertechnetate salivary gland scintigraphy was performed in 145 patients (133 women, 12 men) with clinically suspicious SS. The images were interpreted with visual and semiquantitative methods and the diagnostic performances for SS were compared using uptake and excretory functional parameters.

RESULTS

In total, 76 patients (52.4%) were finally diagnosed with SS. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of visual analysis for the diagnosis of SS were 88.2%, 48.6%, 65.1%, 79.1%, and 69.2%, respectively. Semiquantitative values, the area under the ROC curve for uptake ratio and percentage excretion in the right salivary glands were significantly greater than 0.5 (p < 0.05). However, the percentage excretion in the left salivary glands did not show a statistically significant diagnostic ability for SS. The diagnostic ability of visual assessment was greater than that of the semiquantitative method in terms of evaluating uptake and excretory function in the submandibular glands.

CONCLUSION

Visual analysis of salivary gland scintigraphy showed greater diagnostic utility than semiquantitative assessment in the diagnosis of SS, especially in the submandibular glands.

摘要

未标注

本研究的目的是比较唾液腺闪烁显像的视觉分析与半定量分析在干燥综合征(SS)诊断中的诊断效用。

患者、方法:对145例临床疑似SS的患者(133例女性,12例男性)进行了99mTc-高锝酸盐唾液腺闪烁显像。采用视觉和半定量方法对图像进行解读,并使用摄取和排泄功能参数比较SS的诊断性能。

结果

共有76例患者(52.4%)最终被诊断为SS。视觉分析诊断SS的敏感性、特异性、阳性预测值、阴性预测值和准确性分别为88.2%、48.6%、65.1%、79.1%和69.2%。半定量值方面,右侧唾液腺摄取率和排泄百分比的ROC曲线下面积显著大于0.5(p<0.05)。然而,左侧唾液腺的排泄百分比对SS的诊断能力未显示出统计学意义。在评估下颌下腺的摄取和排泄功能方面,视觉评估的诊断能力大于半定量方法。

结论

在SS诊断中,唾液腺闪烁显像的视觉分析比半定量评估具有更大的诊断效用,尤其是在下颌下腺。

文献检索