Looking for complementary alternatives to CTCAE for skin toxicity in radiotherapy: quantitative determinations.

作者信息

González-Sanchís A, Vicedo-González A, Brualla-González L, Gordo-Partearroyo J C, Iñigo-Valdenebro R, Sánchez-Carazo J, Granero-Cabañero D, Roselló-Ferrando J, López-Torrecilla J

机构信息

Radiation Oncology Department, ERESA, Hospital General Universitario de Valencia (CHGUV), Avenida Tres Cruces, No. 2, 46014, Valencia, Spain,

出版信息

Clin Transl Oncol. 2014 Oct;16(10):892-7. doi: 10.1007/s12094-014-1163-0. Epub 2014 Mar 19.

Abstract

INTRODUCTION

Radiotherapy (RT) is an essential part of the patient's treatment diagnosed with cancer. Determination of the most common RT secondary effect, the cutaneous toxicity, is usually based on visual rating scales, like Common Terminology Criteria for Adverse Events with an inherent subjectivity. The aim of this work is to perform an objective method to evaluate the radiodermatitis using a non-invasive imaging technique based on laser Doppler flowmetry (LDF).

MATERIALS AND METHODS

A prospective study was performed analysing 1,824 measurements. A LDF was used to measure the cutaneous microcirculation in real time. A basal measurement was taken prior to radiotherapy treatment. To be able to observe the microcirculation changes related to the delivered dose, several sets of measurements were taken in the irradiated area along the RT treatment and in the contralateral non-irradiated area.

RESULTS

A relative increase in blood flow at all measured points was found in the irradiated area. This relative increase in blood flow increases with the dose administered. In the non-irradiated contralateral area, the relative increase in blood flow is not significant and is independent of the dose administered. After treatment, a decrease in blood flow was detected with a trend towards returning to the baseline measurements.

CONCLUSIONS

LDF is an objective technique that assesses early radiodermatitis. This method is useful to develop strategies to prevent onset of radiation dermatitis in patients irradiated, such as the modification and individualization of fractionation parameters of the RT. This allows the reduction of radiation morbidities and maintains patient quality of life.

摘要

引言

放射治疗(RT)是癌症患者治疗的重要组成部分。确定最常见的放疗副作用——皮肤毒性,通常基于视觉评分量表,如不良事件通用术语标准,其具有内在的主观性。本研究的目的是使用基于激光多普勒血流仪(LDF)的非侵入性成像技术,建立一种客观评估放射性皮炎的方法。

材料与方法

进行了一项前瞻性研究,分析了1824次测量数据。使用LDF实时测量皮肤微循环。在放疗前进行基础测量。为了观察与所给予剂量相关的微循环变化,在放疗过程中沿着放疗区域以及对侧未照射区域进行了多组测量。

结果

在照射区域所有测量点的血流均出现相对增加。这种血流的相对增加随着所给予剂量而增加。在未照射的对侧区域,血流的相对增加不显著且与所给予剂量无关。治疗后,检测到血流减少,并有恢复到基础测量值的趋势。

结论

LDF是一种评估早期放射性皮炎的客观技术。该方法有助于制定策略,预防接受放疗患者发生放射性皮炎,如调整和个体化放疗分割参数。这有助于减少放疗并发症并维持患者生活质量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验