Askenazi David J, Moore John F, Fineberg Naomi, Koralkar Rajesh, Clevenger Stephanie, Sharer Jon Daniel
Department of Pediatrics Nephrology, University of Alabama at Birmingham, Birmingham, Alabama.
J Clin Lab Anal. 2014 Sep;28(5):405-8. doi: 10.1002/jcla.21701. Epub 2014 Mar 20.
Measurement of serum creatinine (SCr) and urine creatinine (UCr) is regularly used in clinical and research settings. For small animal experiments and for studies in which sample collection is spare (i.e. neonatal cohorts), measuring SCr and UCr using tiny amounts of sample (as low as 10 mcl) would maximize exploration and minimize iatrogenic blood loss.
We performed an evaluation in six healthy adults to determine differences between SCr and UCr values in different methodologies and storage environments and time. Study was conducted using 20 mcl of sample. Analyses were done using two-way repeated measures of ANOVA.
Scr values showed no significant differences between LC/MS vs. Jaffe. However, the SCr using LC/MS method was lowest when measured immediately compared to other time points (F = 7.2; P< 0.001). Similarly, Jaffe measurements showed changes in the mean differences over time; however, these were not significant. UCr values were consistently higher using LC/MS than Jaffe (F = 19; P< 0.01), and UCr changed over time (F = 8.7; P < 0.02). In addition, the interaction term for method and time was also significant (F = 5.8; P < 0.04) which reflects the stability of the Jaffe measurements over time whereas the LC/MS measurements declined; especially after being frozen for 1 year (P < 0.001).
UCr measured by Jaffe is lower than samples measured by LC/MS. UCr measurements by LC/MS vary more over time, mostly due to the sample measured after 1 year; therefore, storage of urine for more than 90 days measured by LC/MS may provide altered results.
血清肌酐(SCr)和尿肌酐(UCr)的测量在临床和研究环境中经常使用。对于小动物实验以及样本采集量有限的研究(即新生儿队列研究),使用微量样本(低至10微升)测量SCr和UCr将最大限度地扩大研究范围并减少医源性失血。
我们对6名健康成年人进行了一项评估,以确定不同方法、储存环境和时间下SCr和UCr值之间的差异。使用20微升样本进行研究。采用双向重复测量方差分析进行分析。
LC/MS法与Jaffe法测得的Scr值无显著差异。然而,与其他时间点相比,采用LC/MS法测得的SCr在立即测量时最低(F = 7.2;P<0.001)。同样,Jaffe测量结果显示平均差异随时间变化;然而,这些差异并不显著。采用LC/MS法测得的UCr值始终高于Jaffe法(F = 19;P<0.01),且UCr随时间变化(F = 8.7;P < 0.02)。此外,方法和时间的交互项也具有显著性(F = 5.8;P < 0.04),这反映了Jaffe测量结果随时间的稳定性,而LC/MS测量结果下降;尤其是在冷冻1年后(P < 0.001)。
Jaffe法测得的UCr低于LC/MS法测得的样本。LC/MS法测得的UCr随时间变化更大,主要是由于1年后测量的样本;因此,采用LC/MS法测量储存超过90天的尿液可能会得出不同的结果。