Department of Endodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
Int Endod J. 2015 Jan;48(1):109-14. doi: 10.1111/iej.12289. Epub 2014 Apr 18.
To compare the shaping ability of WaveOne, Reciproc and OneShape single-file systems in severely curved root canals in extracted human molar teeth.
Sixty mandibular molars with mesio-buccal canals with curvatures ranging between 25° and 35° and radii of curvature ranging between 4 and 9 mm were divided into three groups of 20 teeth each: group W (WaveOne), group R (Reciproc) and group O (OneShape). Using standardized pre- and post-instrumentation radiographs, straightening of canal curvatures was determined using the NIH Image J software. A double-digital standardized radiographic technique was used to determine apical transportation at 0.5 mm from the working length (1.5 mm coronal to the major foramen). Preparation time and instrument failures were also recorded. Data were analysed using one-way analysis of variance (anova) and post-hoc Tukey-test.
During root canal preparation, no instruments fractured but all OneShape instruments were deformed after preparation of four canals. The use of OneShape resulted in significantly greater canal straightening and apical transportation than WaveOne and Reciproc (P < 0.05), with no significant differences between WaveOne and Reciproc (P > 0.05). Instrumentation with OneShape was significantly faster than with WaveOne and Reciproc (P < 0.05), whilst Reciproc was significantly faster than WaveOne (P < 0.05).
All instruments were safe to use. Reciproc and WaveOne instruments respected the original canal curvature better than OneShape files. The use of OneShape instruments required less time to prepare the curved canals compared with Reciproc and WaveOne.
比较 WaveOne、Reciproc 和 OneShape 单锉系统在离体人磨牙重度弯曲根管中的成形能力。
将 60 颗具有颊侧近中根管的下颌磨牙分为三组,每组 20 颗:组 W(WaveOne)、组 R(Reciproc)和组 O(OneShape)。使用标准化的预备前和预备后射线照片,使用 NIH Image J 软件确定根管曲率的拉直情况。采用双数码标准化射线照相技术,在距工作长度(从主孔冠向 1.5mm 处)0.5mm 处确定根尖运输。还记录了预备时间和器械故障。使用单向方差分析(anova)和事后 Tukey 检验对数据进行分析。
在根管预备过程中,没有器械折断,但所有 OneShape 器械在预备四个根管后都变形了。与 WaveOne 和 Reciproc 相比,OneShape 的使用导致根管明显拉直和根尖运输增加(P<0.05),而 WaveOne 和 Reciproc 之间没有显著差异(P>0.05)。OneShape 的器械预备时间明显快于 WaveOne 和 Reciproc(P<0.05),而 Reciproc 则明显快于 WaveOne(P<0.05)。
所有器械的使用都是安全的。与 OneShape 锉相比,Reciproc 和 WaveOne 器械更好地保留了原始根管的曲率。与 Reciproc 和 WaveOne 相比,OneShape 器械在预备弯曲根管时所需时间更少。