Suppr超能文献

不同连续锥度旋转锉系统在严重弯曲根管中根管冠向运输和根管成形效果的比较:F6 SkyTaper 和 OneShape 与 Mtwo 比较。

Apical transportation and canal straightening with different continuously tapered rotary file systems in severely curved root canals: F6 SkyTaper and OneShape versus Mtwo.

机构信息

Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, Münster, Germany.

出版信息

Int Endod J. 2017 Oct;50(10):983-990. doi: 10.1111/iej.12716. Epub 2016 Nov 22.

Abstract

AIM

To compare apical transportation and canal straightening when using three continuous tapered rotary NiTi systems [F6 SkyTaper (Komet/Brasseler, Lemgo, Germany), Mtwo (VDW, Munich, Germany) and OneShape (Micro Méga, Besançon, France)] in severely curved root canals.

METHODOLOGY

A total of 60 root canals in extracted human teeth with angles of curvatures ranging between 25° and 35° and radii ranging between 4 and 9 mm were divided into three groups (n = 20). Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the radius of canal curvature (P = 1.0 and P = 0.994, respectively). All canals were prepared to an apical size 30 according to the manufacturer's instructions. Pre- and post-instrumentation radiographs were superimposed and apical transportation and canal straightening were analysed using a computer imaging program. Preparation time and instrument failure were also recorded. Data were analysed statistically using anova and Student-Newman-Keuls test.

RESULTS

During preparation, no file fractured. All instruments maintained the original canal curvature well with no significant differences between the instruments (P = 0.542). Concerning apical transportation, no significant differences were obtained (P = 0.414). Regarding preparation time, no significant differences were obtained between F6 SkyTaper and OneShape (P > 0.05), but both were significantly faster than Mtwo (P < 0.05).

CONCLUSION

Under the conditions of this study, all instruments respected the original canal curvature well and apical transportation was negligible. Instruments were safe to use. Preparation with F6 SkyTaper and OneShape was faster than with Mtwo.

摘要

目的

比较三种连续旋转镍钛锉(F6 SkyTaper[Komet/Brasseler,利姆戈,德国]、Mtwo[VDW,慕尼黑,德国]和 OneShape[Micro Méga,贝桑松,法国])在重度弯曲根管中根管预备时的根尖偏移和根管偏移。

方法

共纳入 60 个从患者体内拔出的牙齿的根管,这些牙齿的弯曲角度在 25°至 35°之间,根管弯曲半径在 4 至 9 mm 之间。根据器械预备前的 X 光片,将样本分为 3 组(每组 20 个),每组在根管弯曲角度和半径方面进行均衡(P=1.0 和 P=0.994)。所有根管均按制造商的说明预备至 30 号。在预备前后的 X 光片上叠加,使用计算机成像程序分析根尖偏移和根管偏移,并记录预备时间和器械折断情况。采用方差分析和 Student-Newman-Keuls 检验对数据进行统计学分析。

结果

在预备过程中,没有器械折断。所有器械都很好地保持了原始根管的弯曲度,各器械之间无显著差异(P=0.542)。在根尖偏移方面,各器械之间也无显著差异(P=0.414)。在预备时间方面,F6 SkyTaper 和 OneShape 之间无显著差异(P>0.05),但两者均显著快于 Mtwo(P<0.05)。

结论

在本研究条件下,所有器械均很好地保持了原始根管的弯曲度,根尖偏移可忽略不计。器械使用安全。F6 SkyTaper 和 OneShape 的预备速度快于 Mtwo。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验