Masmali Ali, Alqahtani Tahani A, Alharbi Ahmed, El-Hiti Gamal A
Cornea Research Chair (CRC), Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
Eye Contact Lens. 2014 May;40(3):127-31. doi: 10.1097/ICL.0000000000000025.
To investigate the repeatability of the phenol red thread (PRT) and Schirmer tests in healthy Saudi adults. Additionally, we compared the PRT mean value with those reported previously because of significant differences between Hong Kong-Chinese, Japanese, and US subjects.
Thirty healthy young Saudi adults (7 men and 23 women; 60 eyes) with a mean age of 22.37±2.31 years were recruited. Participants provided consent and completed a McMonnies questionnaire. Dry eye subjects were excluded based on this questionnaire and slit-lamp examination. Both eyes of each subject were examined using the PRT and Schirmer tests. Each test was repeated three times for each eye, five minutes apart. The PRT test was applied first, followed by the Schirmer test 15 minutes later under anesthesia to avoid any inconsistency of the measurements due to reflex tears.
The PRT and Schirmer tests both demonstrated good repeatability with no statistically significant differences. There was a poor correlation between the 2 tests (r=0.286). There was no statistically significant difference between OD and OS in the two tests. The mean PRT values in normal Saudi subjects were higher than those reported previously for Hong Kong-Chinese, Japanese, and US subjects.
Both the PRT and Schirmer tests displayed good repeatability; however, there was a poor correlation between the tests, as reported previously. The mean PRT value in normal Saudis was higher, when compared with those reported previously for other ethnic groups.
研究酚红棉线试验(PRT)和泪液分泌试验在沙特健康成年人中的可重复性。此外,由于中国香港人、日本人及美国人之间存在显著差异,我们将沙特人的PRT平均值与之前报道的数值进行了比较。
招募了30名健康的沙特年轻成年人(7名男性和23名女性;60只眼),平均年龄为22.37±2.31岁。参与者签署了知情同意书并完成了麦克莫尼斯问卷。根据该问卷和裂隙灯检查排除干眼受试者。对每位受试者的双眼进行PRT和泪液分泌试验检查。每只眼睛的每项检查重复三次,每次间隔五分钟。先进行PRT试验,15分钟后在麻醉状态下进行泪液分泌试验,以避免反射性泪液导致测量结果出现任何不一致。
PRT和泪液分泌试验均显示出良好的可重复性,无统计学显著差异。两项检查之间的相关性较差(r=0.286)。两项检查中右眼和左眼之间无统计学显著差异。沙特正常受试者的PRT平均值高于之前报道的中国香港人、日本人及美国人的数值。
PRT和泪液分泌试验均显示出良好的可重复性;然而,正如之前报道的那样,两项检查之间的相关性较差。与之前报道的其他种族相比,沙特正常人的PRT平均值更高。