Sobocki Jacek, Nowakowski Michal, Herman Roman M, Wałęga Piotr, Frączek Mariusz, Tuz Ryszard, Schwartz Tomasz, Murawski Maciej
St Anna Memorial Hospital, Warsaw, Poland
St Anna Memorial Hospital, Warsaw, Poland.
Surg Innov. 2015 Feb;22(1):70-6. doi: 10.1177/1553350614530190. Epub 2014 Apr 21.
Modulation of the enteric nervous system seems to be promising in several functional colorectal disorders for which targeted, causal treatment methods do not exist. However, sacral nerve stimulation can induce undesirable muscle contraction or paresthesia. Therefore, we have developed a laparoscopic technique for implanting a neural electrode, placed directly over the pelvic autonomic nerve plexus. The aim of this experimental study was to evaluate the effect of stimulating the hypogastric plexus and pelvic nerves on inducing distal colon contraction, defecation, and micturition.
A total of 10 white, male healthy pigs (25-30 kg) were subjected to the laparoscopic implantation of the electrode and the stimulator. In the third and fourth weeks postimplantation, the efficacy of the acute and chronic stimulation to induce defecation was evaluated.
The average operative time was 105 minutes (85-150 minutes). In all pigs, acute stimulation activated induced defecation, every second day, every time on demand, with an average delay of 139.7 s. Micturition was induced incidentally. Acute or chronic stimulation did not cause any harm, pain, or suffering to the animals. No adverse effects of the stimulation were observed, and no septic complications or macroscopic fibrosis around the electrodes were found on autopsy.
Hypogastric plexus stimulation can be a useful and safe option of distal colon contraction, defecation, and micturition. However, the efficacy of the stimulation was observed for a relatively short period of time, and it is not known if it will be sustained for a longer duration.
对于几种尚无针对性因果治疗方法的功能性结直肠疾病,调节肠神经系统似乎颇具前景。然而,骶神经刺激可诱发不良肌肉收缩或感觉异常。因此,我们开发了一种腹腔镜技术,用于植入直接置于盆腔自主神经丛上方的神经电极。本实验研究的目的是评估刺激腹下神经丛和盆腔神经对诱发远端结肠收缩、排便和排尿的影响。
总共10头体重25 - 30千克的健康白色雄性猪接受了电极和刺激器的腹腔镜植入。在植入后的第三和第四周,评估急性和慢性刺激诱发排便的效果。
平均手术时间为105分钟(85 - 150分钟)。在所有猪中,急性刺激可诱发排便,每隔一天按需进行,平均延迟时间为139.7秒。排尿为偶然诱发。急性或慢性刺激均未对动物造成任何伤害、疼痛或痛苦。未观察到刺激的不良反应,尸检时未发现电极周围有感染并发症或宏观纤维化。
腹下神经丛刺激可能是诱发远端结肠收缩、排便和排尿的一种有用且安全的方法。然而,刺激的效果观察时间相对较短,尚不清楚其是否能长期持续。