Nazari Moghadam Kiumars, Shahab Shahriar, Shirvani Soghra, Kazemi Ali
Department of Endodontics, Dental School, Shahed University of Medical Sciences, Tehran, Iran.
Department of Oral and Maxillofacial Radiology, Dental School, Shahed University of Medical Sciences, Tehran, Iran.
Iran Endod J. 2011 Summer;6(3):116-8. Epub 2011 Aug 15.
The purpose of this study was to evaluate external root surface temperature rise during post space preparation using LA Axxess bur, Beefill pack System, and Peeso Reamer drill.
The distal canals of forty-five extracted human permanent mandibular first molars were instrumented in crown-apical manner and obturated with lateral condensation technique. Teeth were then randomly divided into three groups according to post space preparation technique including: group 1. LA Axxess bur (Sybronendo Co., CA, USA), group 2 Beefill pack System (VD W Co., Munich, Germany) and group 3 Peeso Reamer drill (Mani Co., Tochigi-ken, Japan). Temperature was measured by means of digital thermometer MT-405 (Comercio Co., Sao Paulo, Brazil) which was installed on the root surfaces. Data was collected and submitted to one-way ANOVA and Post hoc analysis.
Root surface temperatures were found to be significantly higher (7.3±2.7 vs. 4.3±2.1 and 4±2.4,) in samples of Beefill pack System compared with the two other groups (P<0.02).
Using Beefill pack System during post space preparation may be potentially hazardous for periodontal tissues.
本研究的目的是评估使用LA Axxess钻针、Beefill充填系统和Peeso扩孔钻进行桩道预备时牙根表面温度的升高情况。
选取45颗拔除的人下颌第一恒磨牙,对其远中根管进行冠向-根尖向预备,并采用侧向加压技术进行充填。然后根据桩道预备技术将牙齿随机分为三组,包括:第1组使用LA Axxess钻针(美国加利福尼亚州Sybronendo公司),第2组使用Beefill充填系统(德国慕尼黑VDW公司),第3组使用Peeso扩孔钻(日本枥木县Mani公司)。通过安装在牙根表面的数字温度计MT - 405(巴西圣保罗Comercio公司)测量温度。收集数据并进行单因素方差分析和事后分析。
发现Beefill充填系统组样本的牙根表面温度显著高于其他两组(7.3±2.7对比4.3±2.1和4±2.4,P<0.02)。
在桩道预备过程中使用Beefill充填系统可能对牙周组织有潜在危害。