Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan.
Laboratory for Comparative Orthopaedic Research, Michigan State University, East Lansing, Michigan.
Sports Health. 2014 May;6(3):256-64. doi: 10.1177/1941738113503442.
Allografts offer several important advantages over autografts in musculoskeletal reconstructive procedures, such as anterior cruciate ligament reconstruction. Despite growing widespread use of allograft tissue, serious concerns regarding safety and functionality remain. We discuss the latest knowledge of the potential benefits and risks of allograft use and offer a critical review of allograft tissue regulation, management, and sterilization to enable the surgeon to better inform athletes considering reconstructive surgery options.
A review of sources published in the past 10 years is the primary basis of this research.
Observational analysis (cohort study).
Level 3.
Comparable outcome data for autografts and allografts do not support universal standards for anterior cruciate ligament reconstruction, and physician recommendation and bias appear to significantly influence patient preference and satisfaction. Sterilization by gamma and electron-beam irradiation diminishes the biomechanical integrity of allograft tissue, but radioprotective agents such as collagen cross-linking and free radical scavengers appear to have potential in mitigating the deleterious effects of irradiation and preserving tissue strength and stability.
Allografts offer greater graft availability and reduced morbidity in orthopaedic reconstructive procedures, but greater expansion of their use by surgeons is challenged by the need to maintain tissue sterility and biomechanical functionality. Advances in the radioprotection of irradiated tissue may lessen concerns regarding allograft safety and structural stability.
同种异体移植物在运动医学重建手术中具有许多优于自体移植物的优势,如前交叉韧带重建。尽管同种异体组织的应用越来越广泛,但对于其安全性和功能仍存在严重担忧。我们讨论了同种异体使用的潜在益处和风险的最新知识,并对同种异体组织的监管、管理和消毒进行了批判性评价,以使外科医生能够更好地向考虑重建手术选择的运动员提供信息。
本研究的主要依据是对过去 10 年发表的资料进行的综述。
观察性分析(队列研究)。
3 级。
自体移植物和同种异体移植物的可比结果数据并不支持前交叉韧带重建的普遍标准,而且医生的建议和偏见似乎明显影响了患者的偏好和满意度。γ和电子束辐照消毒会降低同种异体移植物组织的生物力学完整性,但胶原交联和自由基清除剂等放射保护剂似乎有可能减轻辐照的有害影响并保持组织强度和稳定性。
同种异体移植物在骨科重建手术中提供了更大的移植物可用性和更低的发病率,但外科医生需要保持组织无菌性和生物力学功能,这对同种异体移植物的广泛应用提出了挑战。辐照组织的放射防护方面的进展可能会减轻对同种异体移植物安全性和结构稳定性的担忧。