Suppr超能文献

正常马匹角膜、视网膜和视神经的频域光学相干断层扫描评估

Spectral-domain optical coherence tomography evaluation of the cornea, retina, and optic nerve in normal horses.

作者信息

Pinto Nelson I, Gilger Brian C

机构信息

Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC, 27606, USA.

出版信息

Vet Ophthalmol. 2014 Jul;17 Suppl 1:140-8. doi: 10.1111/vop.12180. Epub 2014 May 14.

Abstract

PURPOSE

To determine the feasibility of using a handheld spectral-domain optical coherence tomography (SD-OCT) instrument to characterize normal corneal, retinal, and optic nerve head anatomy in vivo in standing horses.

METHODS

Clinically normal horses under sedation, palpebral nerve blockage, and pharmacologically induced mydriasis were imaged with a SD-OCT instrument (Envisu SD-OCT, Bioptigen, Inc., Morrisville, NC). Radial volumes from the cornea (axial, superior, inferior, nasal, and temporal), and rectangular volumes from the retina (dorsal, ventral, nasal, and temporal) and optic nerve head were acquired. Manual measurements of the corneal layers within the five regions, retinal and nerve fiber layer thickness in the four different regions adjacent to the ONH, and vertical and horizontal axis of the optic nerve head (ONH) and optic cup (OC) were obtained using the same device.

RESULTS

Total corneal thickness (mean ± SD) measurements were 800 ± 50, 937 ± 61, 956 ± 61, 912 ± 65, and 884 ± 68 μm for the axial, superior, inferior, nasal, and temporal regions, respectively. The highest total retinal and nerve fiber layer thickness (mean ± SD), at the level of the ONH, was found nasally 459 ± 115 and 377 ± 116 μm, respectively, followed by the temporal, dorsal, and ventral quadrants. The dimensions of the ONH and OC (mean ± SD) were 3.682 ± 0.276 and 2.175 ± 0.502 mm for the horizontal, and 3.012 ± 0.278 and 2.035 ± 0.488 mm for the vertical axis.

CONCLUSIONS

The SD-OCT instrument employed in this study may be used on sedated horses and allows the acquisition of high-resolution images, and thickness measurements involving the cornea, retina, and optic nerve.

摘要

目的

确定使用手持式光谱域光学相干断层扫描(SD-OCT)仪器在站立马匹体内对正常角膜、视网膜和视神经乳头解剖结构进行表征的可行性。

方法

对处于镇静、睑神经阻滞和药物性散瞳状态下的临床正常马匹,使用SD-OCT仪器(Envisu SD-OCT,Bioptigen公司,北卡罗来纳州莫里斯维尔)进行成像。获取角膜的径向体积(轴向、上方、下方、鼻侧和颞侧),以及视网膜(背侧、腹侧、鼻侧和颞侧)和视神经乳头的矩形体积。使用同一设备手动测量五个区域内的角膜层、与视神经乳头相邻的四个不同区域的视网膜和神经纤维层厚度,以及视神经乳头(ONH)和视杯(OC)的垂直和水平轴。

结果

轴向、上方、下方、鼻侧和颞侧区域的总角膜厚度(平均值±标准差)测量值分别为800±50、937±61、956±61、912±65和884±68μm。在视神经乳头水平,视网膜和神经纤维层总厚度最高(平均值±标准差)的是鼻侧,分别为459±115和377±116μm,其次是颞侧、背侧和腹侧象限。视神经乳头和视杯的尺寸(平均值±标准差),水平轴分别为3.682±0.276和2.175±0.502mm,垂直轴分别为3.012±0.278和2.035±0.488mm。

结论

本研究中使用的SD-OCT仪器可用于镇静马匹,并能获取高分辨率图像以及涉及角膜、视网膜和视神经的厚度测量值。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验