Suppr超能文献

使用便携式光谱域光学相干断层扫描设备对健康马眼进行手动角膜厚度测量。

Manual corneal thickness measurements of healthy equine eyes using a portable spectral-domain optical coherence tomography device.

作者信息

Pirie C G, Alario A F, Barysauskas C M, Gradil C, Uricchio C K

机构信息

Department of Clinical Sciences, Tufts Cummings School of Veterinary Medicine (TCSVM), North Grafton, Massachusetts, USA.

出版信息

Equine Vet J. 2014 Sep;46(5):631-4. doi: 10.1111/evj.12198. Epub 2013 Dec 9.

Abstract

REASONS FOR PERFORMING STUDY

Corneal thickness measurements of the equine globe using spectral-domain optical coherence tomography (SD-OCT) have not been reported.

OBJECTIVES

To determine corneal thickness measurements and the intra- and interoperator reliability of a portable SD-OCT device in equine eyes.

STUDY DESIGN

Prospective observational study.

METHODS

Horses free of ocular disease were used for this study. Gentle manual restraint, in combination with detomidine hydrochloride and a head stand, were employed to ensure proper animal positioning. Corneal pachymetry measurements were obtained from both eyes of each animal 3 times by 2 operators in succession. A 6 mm corneal pachymetry protocol was performed using a portable SD-OCT device. All measurements were obtained manually by one operator (C.G.P.) using the integrated calliper function. Measurements included epithelial thickness, stromal thickness, Descemet's membrane thickness and total corneal thickness. All recorded measurements were analysed to determine both intra- and interoperator reliability.

RESULTS

Thirty horses with a mean age of 10.6 ± 6.4 years were examined. Mean epithelial, stromal, Descemet's membrane and total corneal thickness values obtained were, respectively, 174.7 ± 13.6, 599.2 ± 45.4, 38.4 ± 15.3 and 812.0 ± 44.1 μm for operator A and 175.9 ± 12.9, 599.2 ± 44.9, 38.4 ± 15.0 and 812.9 ± 42.9 μm for operator B. A positive correlation was found between Descemet's membrane thickness and age, whereby Descemet's membrane thickness increased by 2 μm/year (P<0.0001). The coefficients of variation for both operators were <4% for all measurements. Intraclass correlations ranged from 0.92 to 0.98.

CONCLUSIONS

Manual corneal thickness measurement using a portable SD-OCT device provides epithelial, stromal, Descemet's membrane and total corneal thickness measurements with clinically acceptable intra- and interoperator reliability in healthy equine eyes.

摘要

开展本研究的原因

尚未有关于使用光谱域光学相干断层扫描(SD - OCT)测量马眼球角膜厚度的报道。

目的

确定便携式SD - OCT设备测量马眼角膜厚度的结果以及测量者内和测量者间的可靠性。

研究设计

前瞻性观察性研究。

方法

本研究使用无眼部疾病的马匹。采用温和的手动约束,并联合盐酸右美托咪定和头架,以确保动物体位正确。两名操作者依次对每只动物的双眼进行3次角膜测厚测量。使用便携式SD - OCT设备执行6毫米角膜测厚方案。所有测量均由一名操作者(C.G.P.)使用集成卡尺功能手动完成。测量内容包括上皮厚度、基质厚度、后弹力层厚度和角膜总厚度。对所有记录的测量结果进行分析,以确定测量者内和测量者间的可靠性。

结果

检查了30匹马,平均年龄为10.6±6.4岁。操作者A测得的平均上皮、基质、后弹力层和角膜总厚度值分别为174.7±13.6、599.2±45.4、38.4±15.3和812.0±44.1μm,操作者B测得的分别为175.9±12.9、599.2±44.9、38.4±15.0和812.9±42.9μm。发现后弹力层厚度与年龄呈正相关,后弹力层厚度每年增加2μm(P<0.0001)。两名操作者所有测量的变异系数均<4%。组内相关系数范围为0.92至0.98。

结论

使用便携式SD - OCT设备手动测量角膜厚度,在健康马眼中可提供上皮、基质、后弹力层和角膜总厚度测量结果,且测量者内和测量者间的可靠性在临床可接受范围内。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验