OBJECTIVE

Fractured endodontic instruments inhibit optimal cleaning and filling of dental root canals, which may result in a less favorable prognosis for the tooth. Several techniques are available to remove fractured instruments; however, healthy tooth substance often must be destroyed in the process. This study was intended to evaluate Nd:YAG laser treatment as a method to remove fractured stainless steel instruments without destroying healthy tooth substance.

METHOD AND MATERIALS

Stainless steel endodontic instruments were fractured in 33 unprocessed root canals of mandibular central and lateral incisors and premolars in vitro. A brass tube charged with solder was placed at the coronal end of the fractured instrument and laser energy was used to melt the solder, connecting the fractured instrument with the brass tube. The success rates of connecting and removal of fractured instruments from the root channel were recorded for each case.

RESULTS

Connecting was achieved in every case in which more than 1.5 mm of the fractured instrument was tangible (22 out of 22). In cases where less than 1.5 mm was tangible, the rate for successful connection decreased to 4 out of 11 (36.4%). Fractured endodontic instruments were removed successfully in 17 out of 22 cases (77.3%) in which more than 1.5 mm was tangible. If less than 1.5 mm was tangible, the removal success rate decreased to 3 out of 11 cases (27.3%).

CONCLUSION

Our data support Nd:YAG laser-mediated connecting of a brass tube to a fractured endodontic instrument as a feasible and tissue conserving removal approach when more than 1.5 mm of the instrument is tangible.

摘要

目的

根管内折断器械会妨碍对牙根管进行最佳的清理和充填,这可能导致牙齿预后欠佳。有多种技术可用于取出折断器械;然而,在此过程中常常必须破坏健康的牙体组织。本研究旨在评估钕钇铝石榴石(Nd:YAG)激光治疗作为一种在不破坏健康牙体组织的情况下取出折断不锈钢器械的方法。

方法与材料

在下颌中切牙、侧切牙和前磨牙的33个未处理的离体根管中折断不锈钢根管器械。将装有焊料的铜管置于折断器械的冠端,并用激光能量熔化焊料,从而将折断器械与铜管连接起来。记录每种情况下折断器械与根管连接及从根管取出的成功率。

结果

在折断器械有超过1.5毫米可触及的每种情况下均实现了连接(22例中的22例)。在可触及部分少于1.5毫米的情况下,成功连接率降至ll例中的4例(36.4%)。在折断器械有超过1.5毫米可触及的22例病例中,17例(77.3%)成功取出了折断的根管器械。如果可触及部分少于1.5毫米,取出成功率降至11例中的3例(27.3%)。

结论

我们的数据支持当器械有超过1.5毫米可触及部分时,Nd:YAG激光介导的将铜管与折断的根管器械连接起来是一种可行的、能保护组织的取出方法。